Brocade FC port flapped with multiple errors due to SFP not seated properly
Applies to
- Brocade switch
- FCP
Issue
- Brocade FC port is online and in In_Sync state as per
switchshowoutput.
Index Slot Port Address Media Speed State Proto
============================================================
233 11 25 6vxcxc id N32 Online FC F-Port 1 N Port + 1 NPIV public
- In
porterrshow,disc c3andc3timeout txerrors are seen along withlink failandloss syncfor this port.
/fabos/cliexec/porterrshow:
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
233: 42.2g 52.2g 0 0 0 0 0 0 0 1.4k 6 4 0 0 0 1.4k 0 0 0
- Rx & Tx values are in optimal range as per
sfpshowoutput.
Slot 11/Port 25:
=============
Identifier: 3 SFP
Connector: 7 LC
[..]
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000333-01
[...]
RX Power: -0.9 dBm (807.10uW)
TX Power: 0.4 dBm (1087.50 uW)
- As per fabric logs port went offline & online also lot of Link resets, LR_IN & LR_OUT are seen as well.
Switch 0; Wed Dec 18 02:17:35 2024 IST (GMT+5:30)
23:42:40.741146 SCN LR_PORT(0);g=0x0 LR_IN D0,P0 D0,P0 233 NA
23:42:50.725148 SCN LR_PORT(0);g=0x0 LR_IN D0,P0 D0,P0 233 NA
23:44:54.098248 SCN LR_PORT(0);g=0x0 LR_OUT D0,P0 D0,P0 233 NA
23:54:41.867639 SCN LR_PORT(0);g=0x0 LR_OUT D0,P0 D0,P0 233 NA
02:43:35.902334 SCN Port Offline;rsn=0x4,g=0x454 D0,P0 D0,P0 233 NA
02:43:35.902340 *Removing all nodes from port D0,P0 D0,P0 233 NA
02:43:35.934603 SCN LR_PORT(0);g=0x454 D0,P0 D0,P0 233 NA
02:43:40.879145 SCN LR_PORT(0);g=0x454 D0,P0 D0,P0 233 NA
02:43:40.942477 SCN Port Online; g=0x454,isolated=0 D0,P0 D0,P1 233 NA
02:43:40.942550 Port Elp engaged D0,P1 D0,P0 233 NA
02:43:40.942562 *Removing all nodes from port D0,P0 D0,P0 233 NA
- As per
errdumplogs, port encounteredframe timeout detectederrors and and C3timeout TxC3TXTOerrors, along with theseIO_FRAME_LOSSandIO_LATENCY_CLEARare also seen.
2024/12/18-23:43:10 (IST), [MAPS-1001], 745461, SLOT 2 | FID 128 | PORT 11/25, CRITICAL, switch1, VSP_xcxcx_S0xcxcxR07_xcx-7x, F-Port 11/25, Condition=ALL_TARGET_PORTS(C3TXTO/min>3), Current Value:[C3TXTO, 12 Timeouts], RuleName=defALL_TARGET_PORTSC3TXTO_3, Dashboard Category=Port Health, Quiet Time=None.
2024/12/18-23:43:11 (IST), [AN-1014], 745462, SLOT 2 | FID 128, INFO, switch1, Frame timeout detected, tx port 11/25 rx port 11/20, sid 6xxdd0, did 6xxss1, timestamp 2024-12-18 23:43:11 .
2024/12/18-23:43:17 (IST), [MAPS-1001], 745560, SLOT 2 | FID 128 | PORT 11/25, CRITICAL, switch1, VSP_xcxcx_S0xcxcxR07_xcx-7x, F-Port 11/25, Condition=ALL_PORTS(DEV_LATENCY_IMPACT/NONE==IO_FRAME_LOSS), Current Value:[DEV_LATENCY_IMPACT, IO_FRAME_LOSS, (138 C3TX Timeouts) ], RuleName=defALL_PORTS_IO_FRAME_LOSS_UNQUAR, Dashboard Category=Fabric Performance Impact, Quiet Time=15 min.
2024/12/18-23:59:17 (IST), [MAPS-1005], 745890, SLOT 2 | FID 128 | PORT 11/25, WARNING, switch1, VSP_xcxcx_S0xcxcxR07_xcx-7x, F-Port 11/25, Condition=ALL_PORTS(DEV_LATENCY_IMPACT/NONE==IO_LATENCY_CLEAR), Current Value:[DEV_LATENCY_IMPACT, IO_LATENCY_CLEAR], Rule defALL_PORTS_IO_LATENCY_CLEAR triggered 6 times in 15 min and last trigger time Wed Dec 18 23:55:07 2024, Dashboard Category=Fabric Performance Impact.
- Below troubleshooting steps can be followed to isolate the issue and before proceeding with solution.
- Clean the connectors on either ends and reseat the cable.
- Check the patch panel as well.
- Check if cable passes the fluke meter test successfully.