Skip to main content
NetApp Knowledge Base

Blade going into faulty state on Brocade switch due to CRC errors with Good EOF exceeding the threshold

Views:
42
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade Switch

Issue

  • Blade on slot 6 of Brocade switch goes into faulty state.
  • One of the switch ports on the chip/blade of slot 6 on Brocade switch exceeds the threshold of CRC errors with GoodEOF.
  • Below events are reported under Errdump on Brocade Switch-
2024/11/15-02:27:19 (IST), [C4-1030], 12084732, SLOT 1 | CHASSIS | PORT 6/4, WARNING, Switch, S6,P-1(20): Internal CRC with good EOF errors exceeded threshold, tuning is required. current:0x19, last:0xf000000b thresh2:0x9000000a.

2024/11/15-02:27:19 (IST), [C4-1056], 12084733, SLOT 1 | CHASSIS, CRITICAL, Switch, Chip in Slot 6, Chip 0 getting faulted with reason 52.
2024/11/15-02:27:20 (IST), [EM-1134], 12084734, SLOT 1 | FFDC | CHASSIS, ERROR, Switch, Slot 6 set to faulty, rc=20015.
2024/11/15-02:27:20 (IST), [RAS-1001], 12084735, SLOT 1 | CHASSIS, INFO, Switch, First failure data capture (FFDC) event occurred.
2024/11/15-02:27:20 (IST), [MAPS-1002], 12084736, SLOT 1 | FID 128, ERROR, Switch, Blade 6, Condition=ALL_SLOTS(BLADE_STATE/NONE==FAULTY), Current Value:[BLADE_STATE, FAULTY], RuleName=defALL_SLOTSBLADE_STATE_FAULTY, Dashboard Category=Fru Health, Quiet Time=None.
2024/11/15-02:27:50 (IST), [MAPS-1021], 12084738, SLOT 1 | FID 128, WARNING, Switch, RuleName=defCHASSISFAULTY_BLADE_1, Condition=CHASSIS(FAULTY_BLADE/NONE>=1), Obj:Chassis [FAULTY_BLADE,1] has contributed to switch status MARGINAL.
2024/11/15-02:27:50 (IST), [MAPS-1020], 12084739, SLOT 1 | FID 128, WARNING, Switch, Switch wide status has changed from HEALTHY to MARGINAL.
  • Slotshow -m reports the switch blade on Slot 6 as Faulty-
/fabos/cliexec/slotshow -m:

Slot   Blade Type     ID    Model Name     Status
--------------------------------------------------
  1     CP BLADE    175     CPX6           ENABLED
  2     CP BLADE    175     CPX6           ENABLED
  3     SW BLADE    178     FC32-48        ENABLED
  4     SW BLADE    178     FC32-48        ENABLED
  5     SW BLADE    178     FC32-48        ENABLED
  6     SW BLADE    178     FC32-48        FAULTY (21)
  7     CORE BLADE  177     CR32-8         ENABLED
  8     CORE BLADE  177     CR32-8         ENABLED
  9     SW BLADE    178     FC32-48        ENABLED
10     SW BLADE    178     FC32-48        ENABLED
11     SW BLADE    178     FC32-48        ENABLED
12     SW BLADE    178     FC32-48        ENABLED

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.