BES switch ports offline after power outage
Applies to
Issue
- After site power outage multiple switch ports (ISLs and Intra Cluster ports) are reporting offline and cannot be brought online
The status of interfaces from switch with issues are:
(CSA1)#show interfaces status all
Link Physical Physical Media Flow
Port Name State Mode Status Type Control VLAN
--------- ---------------------- ------ ---------- ---------- ---------- ---------- ----------
...
0/9 Shared Intra-Cluster/M Down Auto Inactive Trunk
0/10 Shared Intra-Cluster/M Down Auto Inactive Trunk
...
0/13 MetroCluster ISL Port Down Auto Inactive
0/14 MetroCluster ISL Port Down Auto Inactive
0/15 MetroCluster ISL Port Down Auto Inactive 1
0/16 MetroCluster ISL Port Down Auto Inactive 1
0/55 Intra-Cluster ISL Port Up Auto 100G Full Copper Inactive Trunk
0/56 Intra-Cluster ISL Port Up Auto 100G Full Copper Inactive Trunk
0/81 Detach 25G Full N/A
The status of interfaces from the switch that Works fine are:
(CSA2)#show interfaces status all
Link Physical Physical Media Flow
Port Name State Mode Status Type Control VLAN
--------- ---------------------- ------ ---------- ---------- ---------- ---------- ----------
...
0/9 Shared Intra-Cluster/M Up 10G Full 10G Full DAC Inactive Trunk
0/10 Shared Intra-Cluster/M Up 10G Full 10G Full DAC Inactive Trunk
...
0/13 MetroCluster ISL Port Up Auto 25G Full Copper Inactive Trunk
0/14 MetroCluster ISL Port Up Auto 25G Full Copper Inactive Trunk
0/15 MetroCluster ISL Port Down Auto Inactive 1
0/16 MetroCluster ISL Port Down Auto Inactive 1
0/55 Intra-Cluster ISL Port Up Auto 100G Full Copper Inactive Trunk
0/56 Intra-Cluster ISL Port Up Auto 100G Full Copper Inactive Trunk
0/81 Detach 25G Full N/A
- The switch is powered on and reachable over console connection
- Switch is running up-to-date Broadcom's Ethernet Fabric OS (EFOS) firmware and NetApp's Reference Configuration File (RCF)
- Ports in NetApp filers are confirmed to be working via loopback
- Bouncing the ports through console (in switch) does not work
- Cabling re-seat does not bring the ports online on the switch side