BES-53248 switch reports link down for 100G interface
Applies to
- Cluster Network Switch model BES-53248
- Broadcom Ethernet Fabric OS (EFOS) version 3.9.0.2, 3.11.1.2
- Reference Configuration File (RCF) v1.9
- MetroCluster IP RCF v2.11
- 100GbE port(s)
Issue
- One licensed network cluster port (49 to 54) at 100GbE is flapping on the switch side.
Example:
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810741 %% NOTE SFP removed from 0/49
Switch-1 DOT1S[dot1s_task]: dot1s_control.c(3088) 4810740 %% INFO Stopping SM on 49
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810739 %% NOTE Link Down: 0/49, Reason Code: 0x40
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810735 %% NOTE Link Up: 0/49
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810732 %% NOTE Link Down: 0/49, Reason Code: 0x40
Switch-1 DOT1S[dot1s_task]: dot1s_control.c(3088) 4810731 %% INFO Stopping SM on 49
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810727 %% NOTE Link Up: 0/49
Switch-1 DOT1S[dot1s_task]: dot1s_control.c(3088) 4810724 %% INFO Stopping SM on 49
- Consequent ONTAP events messages reported for the node ports connected to that switch port:
[Node01: intr: netif.linkDown:info]: Ethernet xxx: Link down, check cable.
[Node01: vifmgr: vifmgr.portdown:debug]: A link down event was received on node Node01, port xxx.
[Node01: vifmgr: vifmgr.clus.linkdown:debug]: The cluster port xxx on node Node01 has gone down unexpectedly.
[Node01: intr: netif.linkUp:info]: Ethernet xxx: Link up.
[Node01: vifmgr: vifmgr.portup:debug]: A link up event was received on node Node01, port xxx.
- Interface
0/49
set to auto negotiate:
(Switch-01)#show port 0/49
Admin Physical Physical Link Link LACP Actor
Intf Type Mode Mode Status Status Trap Mode Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/49 Enable Auto 100G Full Up Enable Enable long
- The issue remains after the cable and SFPs swap/replacement.