StorageGRID alert Storage appliance storage connectivity degraded after unexpected reboot
Applies to
- NetApp StorageGRID
- NetApp E-Series
Issue
- StorageGRID UI reports
Storage appliance storage connectivity degradedafter unexpected compute node reboot. - All port on E-Series backend is UP with no incrementing fibre channel errors in
state-capture-data.txt > fcDump
- In StorageGRID
base-os-logs/command_results.txtis missing paths:
command `multipath -ll` completed with code 0. Output:StorageGRID-obj-00 (xxxxxxxx) dm-3 NETAPP,INF-01-00size=22T features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 alua' wp=rw|-+- policy='service-time 0' prio=50 status=active| |- 17:0:0:222 sdak 66:64 active ready running| `- 18:0:0:222 sdbs 68:96 active ready running`-+- policy='service-time 0' prio=10 status=enabled`- 15:0:0:222 sdc 8:32 active ready runningbase-os-logs/var/log/syslogreports :
2026-08-04T13:57:16.314772+00:00 SG multipathd[2263]: sdx: mark as failed2026-08-04T13:57:16.314824+00:00 SG multipathd[2263]: StorageGRID-obj-11: remaining active paths: 32026-08-04T13:57:16.314848+00:00 SG multipathd[2263]: sdz: mark as failed2026-08-04T13:57:16.314862+00:00 SG multipathd[2263]: StorageGRID-obj-09: remaining active paths: 32026-08-04T13:57:16.314874+00:00 SG multipathd[2263]: sdaa: mark as failed2026-08-04T13:57:16.314886+00:00 SG multipathd[2263]: StorageGRID-obj-08: remaining active paths: 32026-08-04T13:57:16.314904+00:00 SG multipathd[2263]: sdae: mark as failed