LUNs going offline after Host migrations due to incorrect host mappings on E-Series
Applies to
- NetApp E-Series
- SANtricity OS
- Windows Hosts
Issue
- Following a Host migration, reports of LUNs going offline from the Host with direct connections to E-Series array.
- Windows event logs report:
-
Volume needs to be taken offline to perform a Full Disk Check -
A corruption was discovered in the filesystem structure on Volume. The exact nature of the corruption is unknown. The filesystem structure needs to be scanned online
-
-
E-Series
MAJOR-EVENT-LOGreports intermittent Fibre Channel link errors:
B:7/22/26, 11:47:53 AM (11:47:53) 3184 1019 Extended Fibre Channel link down (greater than one minute) - Host-side: controller in bay B, port 3
A:7/22/26, 11:47:52 AM (11:47:52) 3183 1019 Extended Fibre Channel link down (greater than one minute) - Host-side: controller in bay A, port 3
A:7/22/26, 11:45:24 AM (11:45:24) 3180 1019 Extended Fibre Channel link down (greater than one minute) - Host-side: controller in bay A, port 5
B:7/22/26, 11:45:25 AM (11:45:25) 3179 1019 Extended Fibre Channel link down (greater than one minute) - Host-side: controller in bay B, port 5
STORAGE-ARRAY-PROFILE.TXT>HOST-TO-VOLUME ASSIGNMENTSreports Unassociated Host Ports and mappings to old Windows server:-
STORAGE ARRAYUnassociated Host PortsHost Port: 21:00:00:24:ff:xx:xx:xxHost Port: 21:00:00:24:ff:xx:xx:xxHost Port: 21:00:f4:e9:d4:xx:xx:xxHost Port: 21:00:f4:e9:d4:xx:xx:xx
-