E-Series reporting amber LED on external shelf but not reflecting error in recovery guru
Applies to
- NetApp E-Series
- DE224C
Issue
STATE-CAPTURE-DATA->ssmShowSubTree
Executing ssmShowSubTree(4,21,0,0,0,0,0,0,0,0) on controller A:
[Storage Array]
[Enclosure]
Status: Okay
Access Path Status: Okay
Swapped?: No
Predicted Fail?: No
Enclosure Logical ID: 00 00 00 00 00 00 00 00
devAddress: 0x0101
Slot: 1
Parent Slot: 0
Relative Slot: 1
Replacement Policy: Self
Removal Policy: Self
Generic VPD Byte Array: 45 32 38 32 34 20 20 20 20 20 20 20 00 00 00 00 |E2824 ....|
37 32 31 39 34 34 35 30 30 32 30 30 20 20 20 00 |721944500200 .|
4E 45 54 41 50 50 20 20 00 00 00 00 30 37 2F 32 |NETAPP ....07/2|
30 31 39 00 00 00 00 00 4D 49 44 50 4C 41 4E 45 |019.....MIDPLANE|
20 20 20 00 00 00 00 00 00 00 00 00 00 00 00 00 | .............|
00 00 00 00 |.... |
CRU Type: Non-Removable
LED Control: Engenio Encl cfg:0x84
LED State: Present Online
Alarm Control: Off
Component Reported: Yes
Error Rep When Missing: Yes
Attn Request / Attn On: No / No
Last MEL Logged: 0x0 (for Debug ONLY!)
Is Summary Fault On?: No (cfw detected error? No)
Is Summary Attention On?: No (cfw detected error? No)
Executing ssmShowSubTree(4,21,0,0,0,0,0,0,0,0) on controller B:
[Storage Array]
[Enclosure]
Status: Okay
Access Path Status: Okay
Swapped?: No
Predicted Fail?: No
Enclosure Logical ID: 00 00 00 00 00 00 00 00
devAddress: 0x0101
Slot: 1
Parent Slot: 0
Relative Slot: 1
Replacement Policy: Self
Removal Policy: Self
Generic VPD Byte Array: 45 32 38 32 34 20 20 20 20 20 20 20 00 00 00 00 |E2824 ....|
37 32 31 39 34 34 35 30 30 32 30 30 20 20 20 00 |721944500200 .|
4E 45 54 41 50 50 20 20 00 00 00 00 30 37 2F 32 |NETAPP ....07/2|
30 31 39 00 00 00 00 00 4D 49 44 50 4C 41 4E 45 |019.....MIDPLANE|
20 20 20 00 00 00 00 00 00 00 00 00 00 00 00 00 | .............|
00 00 00 00 |.... |
CRU Type: Non-Removable
LED Control: Engenio Encl cfg:0x84
LED State: Present Online
Alarm Control: Off
Component Reported: Yes
Error Rep When Missing: Yes
Attn Request / Attn On: No / No
Last MEL Logged: 0x0 (for Debug ONLY!)
Is Summary Fault On?: No (cfw detected error? No)
Is Summary Attention On?: No (cfw detected error? No)