E-Series drive install or replacement in DE460C DCM3 drawer reports Loss of Path Redundancy or Bypassed Status
Applies to
- NetApp E-Series
- E4000 in DE460C with DCM3 drawers
- Expansion enclosure DE460C with DCM3 drawers
- SANtricity OS: 11.90.R3 or later
Issue
- Drives in the DCM3 drawer may appear with either "Loss of Path Redundancy" or "Bypassed" status after installation or after a drive replacement procedure. A DCM3 drawer can be identified in E-Series AutoSupport or support bundle storage-array-profile under
SHELVESsections.
Drawer status: Optimal Drawer type: Fisher Position: 1 Part number: 111-05610+A3 Serial number: 0425280xxxxx Date of manufacture: Not Available FRU Type: SASDRWR
- E-Series AutoSupport or support bundle reports the events in the major-event-log file as follows:
Event type: 2823Event category: FailurePriority: CriticalEvent needs attention: trueEvent send alert: trueEvent visibility: trueDescription: Drive by-passedEvent specific codes: 0/0/0Component type: DriveComponent location: Shelf 0, Drawer 1, Bay 2Logged by: Controller in bay A
OR
Event type: 282DEvent category: InternalPriority: CriticalEvent needs attention: trueEvent send alert: trueEvent visibility: trueDescription: Drive path redundancy lostEvent specific codes: 0/0/0Component type: DriveComponent location: Shelf 0, Drawer 5, Bay 9Logged by: Controller in bay A