E-Series Recovery guru reports Storage Array Component - Loss of Communication after upgrading the NVSRAM firmware
- Views:
- 20
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-santricity-storage-manager
- Specialty:
- esg
- Last Updated:
Applies to
- E-Series
- StorageGRID appliance
Issue
- Storage node stuck in '
rebooting from maintenance mode' after firmware and NVSRAM upgrade. - Unable to access StorageGRID Appliance Installer page, only SANtricity page is accessible
Thermal sensor on Shelf1 ControllerB reports status UNKNOWN and requires service- Repeated alerts and status changes for temperature sensors and controller components in event logs
- Cluster resilience and performance impacted due to node being down.
Event log excerpt:
FailureEntry1:TEMP_SENSOR_UNKNOWN_STAT-RecoveryFailureTypeCode:61Component reporting problem: Thermal sensor CPUStatus: UNKNOWNLocation: Controller/Drive Shelf1 ControllerB, Bay1Component requiring service: Temperature sensor