Is preventive replacement recommended for an E-Series drive experiencing intermittent controller-side timeouts?

Views:
28
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

NetApp E-Series

Answer

  • Preventive replacement is not recommended for an E-Series drive that only reports intermittent controller-side timeouts.
  • Replace a drive proactively only when an impending drive failure is detected and recorded in the Major Event Log (MEL), including: 
    • Event 2285 - Impending drive failure detected by drive
    • Event 101f - Summary of impending drive failure detected by controller
    • Event 1023 - Drive copy triggered by controller-detected impending drive failure
  • If none of these events are present and no additional symptoms are observed, preventive replacement is not required.
  • E-Series automatically manages drive copy and failure handling when a valid drive failure condition is detected.
  • Updating the drive firmware is recommended to improve stability and timeout recovery behavior.
  • If preventive replacement is required for operational or business reasons, contact NetApp Support to review available options.
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.