E-Series E54xx/E55xx/E27xx/E56xx controller locks down with status of "Memory Parity Error" and 7-segment code sequence "OE L2 CF dx"
Applies to
- E54xx (or E-Series Flash Array Series "EF")
- E55xx (or EF)
- E27xx
- E56xx (or EF)
- All firmware releases
Issue
- Controller locks down with LED code of OE L2 CF dx (x: location of the cache DIMM). This code translates to persistent processor/cache DIMM ECC errors.
- SANtricity System Manager or support bundle reports controller in Memory parity error status.
Status: Memory parity error
- Major event log and exception log if available (
excLogShow
) indicate the controller encountered correctable memory ECC errors before it failed.
Date/Time: **/**/**, 2:54:53 PM
Sequence number: ****
Event type: 2703
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Recoverable error in processor memory detected/corrected
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf **, Bay *
Logged by: Controller in bay *