E-Series reporting degraded drive channel on one or more drives due to faulty drive(s)
Applies to
- NetApp E-Series
- NetApp StorageGRID Appliance
Issue
- E-Series SANtricity System Manager or Storage Manager's indicates array is in needs attention state with one or more entries in
RECOVERY-GURU-PROCEDURES:Individual Drive - Degraded PathController Drive Channel DegradedDEGRADED_DRIVE_CHANNEL-Recovery Failure Type Code: 71DEGRADED_DRIVE_PATH-Recovery Failure Type Code: 76DEGRADED_VOLUME-Recovery Failure Type Code: 13NO_REDUNDANCY_DRIVE-Recovery Failure Type Code: 32VOLUME_HOT_SPARE_IN_USE-Recovery Failure Type Code: 21
Major event logreports one or more alerts:Drive path redundancy lost - Tray 99, Drawer X, Slot XFibre Channel Destination Error - Redundant Path is not available to Device1209 Drive channel set to Degraded - Drive-side: channel 11513 Individual drive - Degraded path - Drive-side: channel 1VDD logged an error100d Timeout on drive side of controllerrepeatedly occurs on a specific drive.
- These steps can also be applied for
Failure Entry 1: BYPASSED_DRIVE-Recovery Failure Type Code: 64andAppliance storage controller hardware issue