E-Series Volume group failure during controller replacement due to loss of drive path
Applies to
E-Series Systems
Issue
- Volume group failed during storage controller replacement
- Amber light observed on drawers prior to replacement.
VOLUME GROUPS------------------------------ SUMMARY Total Volume Groups: 2 Total Capacity: 214.448 TB Usable, 214.446 TB Used Total Free Capacity: 2.553 GB Status: 0 Optimal, 2 Non Optimal Name Status Usable Capacity Used Capacity Free Capacity RAID Level Drive/Media Type Volumes Secure Capable DA Capable VG1 Failed 107.224 TB 107.222 TB 1.776 GB 6 SAS, Hard Disk Drive 1 No Yes VG2 Failed 107.224 TB 107.223 TB 795.527 MB 6
- Few drawers went missing, drives show
loss of redundancy
orbypassed
causing volume groups to fail.
0, 3, 0 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 3, 1 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 3, 2 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 3, 3 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 3, 4 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 3, 5 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 3, 6 Loss of redundancy 7,325.351 GB Hard Disk Drive SAS 12 Gbps HUS728T8TAL5204 NE01 DA 0, 5, 0 By-passed 0, 5, 1 By-passed 0, 5, 2 By-passed 0, 5, 3 By-passed 0, 5, 4 By-passed 0, 5, 5 By-passed 0, 5, 6 By-passed 0, 5, 7 By-passed 0, 5, 8 By-passed 0, 5, 9 By-passed 0, 5, 10 By-passed 0, 5, 11 By-passed
Troubleshooting Steps:
Below steps can be performed one after another. Need to verify if the issue is resolved or not after each step:
- Verify SAS/ Shelf cables connected properly
- Reseat the controller which was replaced to re-establish connections
- Reseat affected drawers one after another
- Powercycle the storage array for clean power-up with all components in place.