Drive shelf attention LED is lighting and the digit number of shelf ID is blinking
Applies to
Issue
- All controller's LEDs are normal
- Drive shelf attention LED is on
- From the seven-segment panel, the second digit number of the shelf ID is blinking
STORAGE-ARRAY-PROFILE
shows shelf ID is "39", but the seven-segment panel shows "90" insteadMAJAR-EVENT-LOG
shows the shelf ID keeps changing frequently
...
Line 3643: B:6/26/22, 2:10:57 PM (14:10:57) 16508 505c Shelf ID changed - Shelf 39
Line 3644: A:6/26/22, 2:09:31 PM (14:09:31) 16507 505c Shelf ID changed - Shelf 7
Line 3645: A:6/26/22, 2:08:49 PM (14:08:49) 16506 505c Shelf ID changed - Shelf 97
Line 3646: A:6/26/22, 2:08:28 PM (14:08:28) 16505 505c Shelf ID changed - Shelf 93
Line 3647: A:6/26/22, 2:07:36 PM (14:07:36) 16504 505c Shelf ID changed - Shelf 85
Line 3648: B:6/26/22, 2:07:03 PM (14:07:03) 16503 505c Shelf ID changed - Shelf 55
Line 3649: B:6/26/22, 2:06:42 PM (14:06:42) 16502 505c Shelf ID changed - Shelf 41
Line 3650: B:6/26/22, 2:05:40 PM (14:05:40) 16501 505c Shelf ID changed - Shelf 81
Line 3651: B:6/26/22, 2:05:19 PM (14:05:19) 16500 505c Shelf ID changed - Shelf 51
Line 3652: B:6/26/22, 2:04:58 PM (14:04:58) 16499 505c Shelf ID changed - Shelf 41
Line 3653: B:6/26/22, 2:04:17 PM (14:04:17) 16498 505c Shelf ID changed - Shelf 51
Line 3654: B:6/26/22, 2:03:55 PM (14:03:55) 16497 505c Shelf ID changed - Shelf 55
...