Chassis Overtemperature Alerts Due to IO2 25G CX7 Temp Faulty PCIe Card Sensor
Applies to
- NetApp ASA-A30/AFF-A30 systems
- ONTAP 9
Issue
The system repeatedly reports chassis overtemperature alerts, which clear within minutes. These alerts include:
[Node1:monitor:monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high.[Node1:env_mgr:monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: IO225GCX7 Temp is warning high (98-103C).[Node1:env_mgr:callhome.chassis.hitemp:error]: Callhome for CHASSIS OVERTEMPERATURE [Node1:env_mgr:monitor.chassisTemperature.ok:notice]: Chassis temperature is ok. [Node1:notifyd:asup.throttle.drop:notice]: Too many AutoSupport messages in too short a time, throttling AutoSupport. hsamcmd--fault-show-all1 bmc/chassis-1/controller-b/pcie-2 25G42_CX7_Temp: Temperature Sensor 164 UNC1 Mon Mar 16 12:41:38 2026Fault Lights On: /chassis-1/controller-b/pcie-2
- System continues to serve data, but monitoring teams receive hundreds of alert emails.
- Room temperature is normal; only one node is affected.