Skip to main content
NetApp Knowledge Base

Cannot Access the HCC & Pings to the MVIP and SVIP Fail

Views:
88
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

  • SolidFire/HCI Element OS
  • SolidFire/HCI management node (mNode)
  • SolidFire/HCI Hybrid Cloud Control (HCC)

Issue

•  An email is received from alerts@hci.netapp.com
Subject: "[External] collector detected" 1 alert(s) on [cluster_name]  (Warning)
 
Partial email body
 c o l l e c t o r   d e t e c t e d   1   a l e r t ( s )   o n   [ c l u s t e r _ n a m e ] 
 
 ( 1 )   c l u s t e r _ n a m e 
 A l e r t :   1   o f   1 
 S t a t u s :   A l e r t   R e m i n d e r   N o t i f i c a t i o n 
 A l e r t   I D :   5 3 6 c 7 8 f 2 - 5 9 b 2 - 4 c 0 7 - a c 2 a - c d c a 9 3 3 a e a 1 4 
 A l e r t   P o l i c y :   c o l l e c t o r 
 S e v e r i t y :   W a r n i n g 
 
 C l u s t e r :  c l u s t e r _ n a m e  < h t t p s : / / u r l d e f e n s e . c o m / v 3 / _ _ h t t p s : / / a c t i v e i q . s o l i d f i r e . c o m / * / c l u s t e r / 1 9 1 3 3 1 9 / d a s h b o a r d _ _ ; I w ! ! O r x s N t y 6 D 4 m y ! 4 d f _ g T E q K a 3 O 1 K G 8 x D T A T d - V o b a 9 X z d z J G s m 8 G 4 E q x O W P D 3 U G F r 3 q 8 q o - u i j w n O I h C h l h o o 7 7 D 8 _ M b j i k z P 6 K j E $ >   
 
 O c c u r r e n c e   T i m e :   2 0 2 4 - 0 9 - 0 4   0 1 : 2 4 : 5 7   U T C 
 N o t i f i c a t i o n   T i m e :   2 0 2 4 - 0 9 - 1 3   2 1 : 1 5 : 2 3   U T C 
 
  A d d i t i o n a l   D e t a i l :   

 *      t h r e s h o l d :   4   h o u r s   o f   i n a c t i v i t y 
 *      i n a c t i v e I n t e r v a l :   1 4 3 9 0   m i n u t e s 
 *      l a s t R e p o r t e d T i m e s t a m p :   2 0 2 4 - 0 9 - 0 3 T 2 1 : 2 4 : 5 4 . 7 0 1 Z 
 
 H i s t o r i c a l   D e t a i l :   T h i s   a l e r t   h a s   o c c u r r e d   0   t i m e s   i n   t h e   l a s t   3 0   d a y s ...
 
•  Pings to the management virtual IP interface (MVIP) and/or storage virtual IP interface (SVIP) fail
 
•  When accessing the Hybrid Cloud Control (HCC), the following error is observed:
 
clipboard_e7024690e6bfdd26fbdef09bc30e2075b.png
 
cluster_name cannot be reached, causing some information to be unavailable. Check the power state and network connectivity for all nodes and ensure in vCenter that the witness node virtual machine is powered on, if applicable.

Error Details:

"code": "inventory. storageInventoryError",
"message": "Error getting 6721d667-15d0-4318-8966-e9de860d230e info from storage-service: Error getting storage info: 424 Client Error: FAILED DEPENDENCY for url: http://:
'parameters": [
"6721d667-15d0-4318-8966-e9de860d230e",
"cluster_name",

 
"IP_addess"

 •  However, external pings to individual management IP (MIP) interfaces and storage IP (SIP) interfaces succeed

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.