AIQUM fails to start the acquisition service with error "Failed to start acquisition - Failed to load certificates" and webUI issues
Applies to
- Active IQ Unified Manager(AIQUM)
Issue
- Error received when trying to start the NetApp Active IQ Acquisition Service
Windows could not start the NetApp Active IQ Acquisition Service on Local Computer.
- "Error loading cluster Dropdown" seen in AIQUM server
- The cluster list under "Cluster Setup" is empty.
- From
au.log
, one or more of the following errors may be present.
ERROR [WrapperStartStopAppMain] c.o.s.a.f.Main (Main.java:66) - Main - failed to start services: Failed to start acquisition - Failed to load certificates java.io.IOException: DerInputStream.getLength(): lengthTag=109, too big
2021-03-08 17:29:23,630 INFO [main] c.o.s.a.f.m.CertificateDownloader (CertificateDownloader.java:88) - Download and install certificate for IP localhost
2021-03-08 17:29:23,637 INFO [main] c.o.s.a.f.m.CertificateDownloader (CertificateDownloader.java:125) - certificate was added to key store using alias 'localhost-1
2021-03-08 17:29:23,638 ERROR [main] c.o.s.a.f.m.CommunicationManager (CommunicationManager.java:396) - null java.io.IOException: No space left on device
Wrapped by: com.onaro.sanscreen.acquisition.framework.FrameworkException: Failed to save key store
2021-03-08 17:44:44,586 ERROR [main] c.o.s.a.f.Main (Main.java:162) - Main - Failed to start acquisition - Failed to load certificates java.io.IOException: Short read of DER length
ocumserver.log:
Error from ocum server logs: 2023-05-31 13:31:14,367 INFO [oncommand] [task-scheduler-8] [c.n.s.service.MemoryMonitorService] AU JVM memory will not be checked for space since enough samples are not available after a JVM restart
Log locations can be found in What are the notable log files and their respective locations for Active IQ Unified Manager?