How access to FabricPool data on StorageGRID is impacted by MetroCluster failover?

Views:
395
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

Applies to

  • NetApp MetroCluster (MCC)
  • NetApp StorageGRID
  • FabricPool

Answer

In the event of a complete site A failure, FabricPool will read/write to the mirror buckets in site B.

Even if storage pool and region are configured to force data to be stored in the desired site, it does not break global namespace access from another site, unless IP based restriction are configured in the bucket policy, buckets will be accessible from another site as long as both StorageGRID sites are running.
 
Note that data will be served cross WAN (though MCC should be low latency) if it is accessed from another data center.

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.