StorageGRID compute node fails to boot after SANtricty OS upgrade
Applies to
StorageGRID Appliances
Issue
After upgrade of SANtricity OS using maintenance mode, the storage node doesn't boot
Bycast.log
[ 381.951774] XFS (dm-3): Ending clean mount
[ 390.370301] XFS (dm-2): Corruption warning: Metadata has LSN (-1179606016:-1157565695) ahead of current LSN (10678:471485). Please unmount and run xfs_repair (>= v4.3) to resolve.
[ 390.503105] XFS (dm-2): Metadata CRC error detected at xfs_bmbt_read_verify+0x15/0xc0 [xfs], xfs_bmbt block 0x2f526ef8
[ 390.513837] XFS (dm-2): Unmount and run xfs_repair
[ 390.518606] XFS (dm-2): First 128 bytes of corrupted metadata buffer:
[ 390.594290] XFS (dm-2): metadata I/O error in "xfs_trans_read_buf_map" at daddr 0x2f526ef8 len 8 error 74
[ 478.663162] XFS (dm-2): Corruption warning: Metadata has LSN (-1179606016:-1157565695) ahead of current LSN (10678:471812). Please unmount and run xfs_repair (>= v4.3) to resolve.