Update installation timed out on PA node during hotfix on StorageGRID
Applies to
- NetApp StorageGRID
- VMware Admin Nodes
- 11.8.0.x Hotfix
Issue
- StorageGRID GUI > Maintenance > System > Software Update reports:
An error occurred during the most recent StorageGRID hotfix. You must retry the StorageGRID hotfix before you can upgrade to a new StorageGRID release or upgrade SANtricity OS. If you cannot apply the hotfix,contact technical support.
- StorageGRID GUI > Maintenance > System > Software update > StorageGRID hotfix > Apply hotfix reports:
StorageGRID hotfix deployment completed with errors: Failed to apply the update to one or more nodes.
- Hotfix Installation Progress for Primary Admin (PA) node reports:
Error: Update installation timed out on [node_name]

nms.latest.logindicates connection timeout during Hotfix:
Jun 20 12:46:30 [node_name] NMS: |2024-06-20T12:46:30.832| ERROR Failed to open TCP connection to localhost:9500 (Connection refused - connect(2) for "localhost" port 9500) (Errno::ECONNREFUSED)
gdu-server.logreports following timeout:
E, [2024-06-20T12:46:40.757092 #3315767] ERROR -- install: Error processing hotfix
E, [2024-06-20T12:46:40.757150 #3315767] ERROR -- install: Failed to execute sh command with 'run-host-command /var/local/dkr/0/tmp/hotfix-stage/hotfix/base-os-install --apply 2>&1 2>&1' on localhost - 127, bash: line 1: /var/local/dkr/0/tmp/hotfix-stage/hotfix/base-os-install: No such file or directory