StorageGRID unable to communicate with node due to SANtricity unexpected reboot
Applies to
- StorageGRID 11.6 appliance
- SANtricity 11.70.3
Issue
- One StorageGRID storage node reports "
Unable to communicate with node
" alert - StorageGRID Appliance installer can be accessed by the default password (admin/bycast), but no Reboot into StorageGRID button shown in GUI
- The 7-segment display of the effected storage controller shows
HO
status - StorageGRID OS can't be recognized and
lumberjack\PGE\syslog
reports the below event during startup
MM DD hh:mm:ss StorageGRID-PGE root: [YYYY-MM-DD hh:mm:ss SGA] StorageGRID is NOT installed.
- SANtricity MEL reports a watchdog reset event
A:M/DD/YY, h:mm:ss AM 1778 4010 Controller reset - Shelf 99, Bay A ----> Reboot Reason : CMGR: REBOOT_CMGR_BY_WATCHDOG_TRIGGER
grid/servermanager.log
indicates that chunk and ldr service detect problem on rangedb(s)
verify storage problem: /var/local/rangedb/N not mounted.