StorageGRID SGF6112 installation failing due to missing disks
Applies to
- NetApp StorageGRID
- SGF6112 appliance
Issue
- The affected storage node is in pre-GRID environment (PGE) state and cannot complete installation.
- Error observed during new installation:
"One or more drives are missing or unresponsive, and there aren't enough good drives to locate and boot an existing StorageGRID installation. You must correct this condition. The missing or unresponsive drives are HDD0X" - In LumberjackPGE logs >
/tmp/lumberjack/PGE: sgalocalstoragetool.logreports no drive found:
2025-04-08|12:47:41|notice|load_g_slot_to_bdev | 2275| no drive found for slot HDD04
2025-04-08|12:47:41|notice|load_g_slot_to_bdev | 2275| no drive found for slot HDD05
sgalst-last-recovery.jsonreports two missing drives in two bays:
"HDD04:state": "missing",
"HDD04:warning:missing_or_unresponsive_drive": "true",
"HDD05:state": "missing",
"HDD05:warning:missing_or_unresponsive_drive": "true",
provision.logreports skipping install:
[2025-04-08 12:27:00+00:00 SGA] Boot action from sgalocalstoragetool: 'halt_in_installer_with_clobber_warning'[2025-04-08 12:27:00+00:00 SGA] Clobber warning token from sgalocalstoragetool: 'missing_or_unresponsive_drive'[2025-04-08 12:27:00+00:00 SGA] Clobber warning data from sgalocalstoragetool: 'HDD04 HDD05 '[2025-04-08 12:27:00+00:00 SGA] Local RAID is missing or broken, or a reboot is needed; not mapping volumes[2025-04-08 12:27:14+00:00 SGA] Skipping StorageGRID install check because a platform issue was detect during boot[2025-04-08 12:27:15+00:00 SGA] [2025-04-08T12:27:14.988] - WARNING -- Failed to get SG OS LUN path. Device /dev/mapper/StorageGRID-SG-OS does not exist[2025-04-08 12:27:15+00:00 SGA] [2025-04-08T12:27:14.988] - INFO -- Not loading synced data from SG OS LUN. Device does not exist