SANtricity System Manager Web UI Unresponsive due to Excessive iSCSI Session Activity
Applies to
- NetApp E-series
- NetApp Santricity System Manager
Issue
- When accessing the SANtricity System Manager Web UI, users encounter persistent loading issues. The UI either displays a continuous spinning animation or the error:
Data Could Not be Loaded from Storage Array
- Attempts to resolve the issue by doing below are only temporarily successful (UI accessible for ~10 minutes), then the issue recurred.:
- Clearing
/msw_data/bdbfolder and restarting the msw service - Firmware upgrade
- Direct laptop connection to controller management port
- ASUP logs and controller webserver logs show a flood of connect/disconnect events and excessive REST API GET requests.
Example iSCSI session logs:
NOTE: Newconn: ... iqn.2016-04.com.open-iscsi:6eXXXbe6XaXX ...
NOTE: Closingconn: ... reason: TcpFinRcvd
NOTE: SessionTimer:CloseSession ... Time2Retain timer of 20 seconds expired.
Most connect/disconnect events are traced to host gxxx-lxx-bxxxxxx (Linux DM-MP, iSCSI initiator: iqn.2016-04.com.open-iscsi:6eXXXbe6XaXX).