500 Internal Server Error attempting to decommission site on StorageGRID
Applies to
Issue
- When accessing the Decommission page, the following error is observed:
500: Internal Server Error
Unable to find storage grades map for site "XXX1a"
- An additional alert is observed attempting to create a storage pool on the same site:
Error
TypeError:Cannot read properties of undefined (reading 'displayName')
/var/local/logs/nms.log
records the following:
nms.latest.log:Mar12 17:32:40 adminnode NMS: |2025-03-12T17:32:40.972| INFO Assigning the selected storage grades to Storage Nodes
nms.latest.log:Mar12 17:32:40 adminnode NMS: |2025-03-12T17:32:40.974| INFO No non-default storage grades to assign.
nms.latest.log:Mar12 17:32:40 adminnode NMS: |2025-03-12T17:32:40.975| INFO Storage grade to Storage Node assignment complete
nms.latest.log:Mar12 20:27:56 adminnode NMS: |2025-03-12T20:27:56.726| ERROR Failed to gather ILM information for site:XXX1a: Unable to find storage grades map for site "XXX1a"
nms.latest.log:Mar12 20:27:56 adminnode NMS: |2025-03-12T20:27:56.726| ERROR Unable to find storage grades map for site"XXX1a" (RuntimeError)