Storage appliance storage connectivity degraded with no fibre channel link errors
Applies to
- NetApp StorageGRID
- NetApp E-Series
Issue
- StorageGRID Grid Manager reports the following alert:
Storage appliance storage connectivity degraded
There is a problem with one or more connections between the compute controller and storage controller.
- Single port reporting I/O errors and multipathing failures in
base-os-logs/var/log/syslog
:
localhost kernel: [13197849.114355] sd 0:0:0:249: [sdn] tag#512 FAILED Result:hostbyte=DID_ERROR driverbyte=DRIVER_OK cmd_age=0s
localhost kernel: [13197849.114363] blk_update_request: I/O error, dev sdn,sector 15257715728 op 0x0:(READ) flags 0x84700 phys_seg 16 prio class 0
localhost multipathd[2671]: sdn: mark as failed
localhost multipathd[2671]: StorageGRID-obj-0x: remaining active paths: 1
localhost multipath: StorageGRID-obj-0x: adding new path sdn
localhost multipath: StorageGRID-obj-0x: adding new path sdaf
localhost multipathd[2671]: StorageGRID-obj-0x: sdn - rdac checker reports path is up
localhost multipathd[2671]: 8:208: reinstated
localhost multipath: StorageGRID-obj-0x: adding new path sdn
localhost multipathd[2671]: StorageGRID-obj-0x: remaining active paths: 2
localhost multipath: StorageGRID-obj-0x: adding new path sdaf
localhost kernel: [13197854.132570] sd 0:0:0:249: alua: port group 00 state A non-preferred supports TolUsNA
- No Fibre channel link errors reported in Major Event Log on E-Series controller