Issue

  • SG5800 uses 25GbE iSCSI for interconnect ports.
  • SG6100 uses a storage interconnect port 100 GbE, connected to 4x25GbE iSCSI breakout cable.
  • StorageGRID Grid Manager reports the following alert:
Storage appliance storage connectivity degraded
There is a problem with one or more connections between the compute controller and storage controller.
  • SANtricity System Manager > Hardware > Show Back of Shelf > Controller > Show Settings > Host Ports show port(s) Down.
  • In ASUP > storage-array-profile > controllers reports link status on affected port(s) as disconnected:
Host interface: iSCSI
Host Interface Card(HIC): Baseboard
Channel: 2 
Port: e0b
Link status: Disconnected    
 
  • In ASUP > state-capture-data.txt > ionShow99 > chall 0 reports no connection to affected port(s):

Executing ionShow(99,0,0,0,0,0,0,0,0,0) on controller B:
-> chall 0

chAll (Tick 0131460364) ==> 12/11/24-12:51:16
4000-B 08.81.00.02
.....Channels.....:...........Target...........:............Initiator..........:                          
             Link :ITN :..........IOs..........:ITN :............IOs...........:.........Busy.........Idle.
  Ch H/D STP Down :cnt : Open  Completed  Errs :cnt : Qd  Open  Completed  Errs:           Ms           Ms
---- --- --- ---- :--- :----- ---------- ----- :--- :--- ----- ---------- -----: ------------ -------------
   0 Drv SAS    0 :  1 :    0        124     0 : 62 :  0     0        915     0:       153616            0
   1 Drv SAS    0 :  1 :    0        125     0 : 62 :  0     0        922     0:          728       152888
-< 2 Hst iSC    0 :  0 :    0          0     0 :  0 :  0     0          0     0:            0       153617-< 3 Hst iSC    0 :  0 :    0          0     0 :  0 :  0     0          0     0:            0       153617
   4 Drv iSA    0 :  0 :    0          0     0 :  1 :  0     0          0     0:            0       153617

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.