StorageGRID Node in Unknown state and Unable to communicate with node alert during power maintenance
Color Definition

Applies to
NetApp StorageGRID
Issue
- StorageGRID generated an
Unable to Communicate with Nodealert during planned power maintenance, with multiple services reported as unresponsive, includingjaegeragent, node, chunk, ssm, dynip, miscd, nginx, jmx, ldr, dds, and dmv. - A
Power Supply Has a Problemalert existed on PSU0 when maintenance activity was performed on the alternate PDU/power source (PSU1). - The node does not respond to ping or SSH and BMC is unreachable.
- The affected node appears in an
Unknownstate in Grid Manager and is no longer communicating with the GRID.
Additional Information
Important Note: StorageGRID appliances use dual power supplies to provide power redundancy and reduce the risk of a single point of failure.
Before performing any power-related maintenance:
- Verify that both redundant power feeds are available and operational.
- In Grid Manager, confirm that there are no active power-supply or power-related alerts.
- Do not proceed with maintenance if power redundancy is degraded or a power-related alert is active.