StorageGRID Compute Node Stuck in Reboot Loop After SANtricity OS Upgrade
Applies to
- StorageGRID SG6000Appliances
- SANtricity OS 11.90R3
Issue
After performing a SANtricity OS upgrade on an E-Series, compute node entered in a continuous reboot loop.
Example Log Output:
SEL Event Logs:
[Warning][PCIeError][CriticalInterrupt] BusCorrectableError(BusAE/Dev0/Fun0)-Asserted[Information][ExtendedPCIeError][OEMRecordC0] ManufacturerID:001C4C/VID:8086/DID:2030/ErrorID1:50/SlotNo:3-1
SYSLOG:
[Hardware Error]: Hardware error from APEI Generic Hardware Error Source: 0
[Hardware Error]: event severity: corrected
[Hardware Error]: Error 0, type: corrected
[Hardware Error]: section_type: PCIe error
[Hardware Error]: port_type: 4, root port
[Hardware Error]: version: 3.0
[Hardware Error]: command: 0x0547, status: 0x0010
[Hardware Error]: device_id: 0000:ae:00.0
[Hardware Error]: slot: 49
[Hardware Error]: secondary_bus: 0xaf
[Hardware Error]: class_code: 060400
pcieport 0000:ae:00.0: AER: aer_status: 0x00000041, aer_mask: 0x00000000
pcieport 0000:ae:00.0: [ 6] BadTLP
mlx5_core 0000:af:00.1 hic1: mlx5e_get_module_eeprom_by_page: mlx5_query_module_eeprom_by_page failed:0xfffffffb