StorageGRID Appliance upgrades fail due to certificate validation errors
Applies to
- NetApp StorageGRID Appliances: SG57xx, SG58xx, SGF6024 and SG6x60
- SANtricity OS 11.80x, 11.80.1x (GA, R1, R2 and R3), and 11.90x (pre-R2).
- SANtricity OS Upgrade
- NVSRAM Upgrade
- Drive Firmware Upgrade
Issue
- StorageGRID Appliance SANtricity OS, NVSRAM or Drive firmware upgrade fails due to certificate failing authentication.
- StorageGRID UI reports the following alerts when attempting to apply SANtricity OS version 11.80.1R2 or later via Grid Manager:
- Maintenance > Software update:
"An error occurred during the most recent SANtricity OS upgrade. You must retry the SANtricity OS upgrade before you can apply a hotfix or upgrade to a new StorageGRID release. If you cannot upgrade SANtricity OS, contact technical support."

- The E-Series event logged located in System Manager Support section (Events) and the
MAJOR-EVENT-LOGin support bundle indicate the firmware package failed authentication check.
A:4/7/25, 12:45:02 PM (12:45:02) 8695 5085 The drive firmware package failed to authenticate using the provided public key and signature - Shelf 99, Bay A <--
A:4/7/25, 12:45:30 PM (12:45:30) 8698 5083 A certificate failed authentication - Shelf 99, Bay A
A:4/7/25, 12:45:32 PM (12:45:32) 8699 5085 The drive firmware package failed to authenticate using the provided public key and signature - Shelf 99, Bay A <--CRITICAL