StorageGRID Appliance compute controller needs attention due to PSU failure on SG6160 SG110 and SG1100
Applies to
- StorageGRID 11.9.x, 11.8.x, 11.7.x
- SG6160, SG110, and SG1100.
Issue
- Grid Manager shows alert:
Appliance compute controller needs attentionAppliance storage controller hardware issueAppliance compute controller power supply A has a problemAppliance compute controller power supply B has a problem
- BMC UI does NOT show any issues with PSU.
- No PSU failure alert is triggered in Grid Manager.
/var/local/log/bycast.logshows:
Aug 27 09:23:13 SGnode24 ADE: |21043885 1600958990 RSMR %CEA 2025-08-27T09:23:13.954179| WARNING 0076 CCST: Unknown status for ipmi sensor: PSU0_StatusAug 27 09:23:13 SGnode24 ADE: |21043885 1600958990 RSMR %CEA 2025-08-27T09:23:13.954203| WARNING 0283 CCST: IPMI device Watchdog reports non-OK status 'reserved' 'reserved'Aug 27 09:23:13 SGnode24 ADE: |21043885 1600958990 RSMR %CEA 2025-08-27T09:23:13.954207| WARNING 0283 CCST: IPMI device CPU0 reports non-OK status 'SM BIOS `Uncorrectable CPU-complex Error'' 'Processor PresenceAug 27 09:23:13 SGnode24 ADE: |21043885 1600958990 RSMR %CEA 2025-08-27T09:23:13.954222| WARNING 0283 CCST: IPMI device Power_BP reports non-OK status 'At or Below (<=) Lower Non-Recoverable Threshold'- In StorageGRID logs
base-os-logs\var\local\gemini-system-status\status.jsonreports:"name": "CPU0","type": "Processor","reading": "N/A","units": "N/A","event": "'SM BIOS `Uncorrectable CPU-complex Error'' 'Processor Presence"