Skip to main content
NetApp Knowledge Base

SCV restore fails due to a permissions error preventing clone volume creation

Views:
100
Visibility:
Public
Votes:
0
Category:
snapcenter
Specialty:
snapx
Last Updated:

Applies to

  • SnapCenter Plug-in for VMware vSphere (SCV) 6.0
  • VMFS datastore over Fibre Channel (FC)
  • Using administrator account in vSphere Client

Issue

  • SCV restore job fails with error:
Error: Exception while calling pre-restore on SCV: Unable to mount datastores: <DATADSTORE> in Backup: <BACKUP_ID>&1.Failed to create LUN clone : No input ESX initiator Ids.
  • vmcontrol_<Job_ID>.log shows errors:

DEBUG <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : AdapterType : FCP
DEBUG <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : AdapterType(): FCP
...
ERROR <HOSTNAME> --- [p1738236591-597] c.n.a.s.c.SnapManagerStorageServiceImpl  : [JobId:<JOB_ID>] Mount Backup failed: Error: The storage system is not registered or configured, or the current user does not have the required permissions. Verify that the storage system is assigned and accessible to the current user.

ERROR <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : [JobId:<JOB_ID>] Failed to create LUN clone <LUN> on volume <IP>:/vol/<VOLUME>/<LUN> Error: The storage system is not registered or configured, or the current user does not have the required permissions. Verify that the storage system is assigned and accessible to the current user.

ERROR <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : [JobId:<JOB_ID>] Failed to create LUN clone <LUN> on volume <IP>:/vol/<VOLUME>/<LUN> Error: The storage system is not registered or configured, or the current user does not have the required permissions. Verify that the storage system is assigned and accessible to the current user.

DEBUG <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : retry with different adapter type:ISCSI
DEBUG <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : AdapterType(): ISCSI
...
ERROR <HOSTNAME> --- [p1738236591-597] c.n.a.s.c.SnapManagerStorageServiceImpl  : [JobId:<JOB_ID>] No input ESX initiator Ids
ERROR <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : [JobId:<JOB_ID>] No input ESX initiator Ids
DEBUG <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : second time try also fail, put the datastore name to failedDatastoreMounts.....
DEBUG <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : Cloned LUN failed!
ERROR <HOSTNAME> --- [p1738236591-597] c.n.a.m.VmfsMountStrategy                : [JobId:<JOB_ID>] Failed to create LUN clone : No input ESX initiator Ids

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.