OnCommand Insight is unable to connect to export tool of Hitachi VSP 5000 series
Applies to
- OnCommand Insight (OCI) 7.3.5
- Hitachi VSP 5000 series
Issue
When OCI tries to acquire data from the export tool via a performance acquistion, we see the following error in C:\Program Files\SANscreen\acq\log\acq.log
<date> ERROR [com.onaro.sanscreen.acquisition.framework.datasource.BaseDataSource] Error 1 out of 1: <name> [Error retrieving data] - Export utility returned with an exit code of: 101 with stdout: Loading ExportTool...
Missing svpip
and stderr: null ([Device name <device>]: Export utility returned with an exit code of: 101 with stdout: Loading ExportTool...
Missing svpip
and stderr: null)
com.onaro.sanscreen.acquisition.framework.datasource.DataSourceErrorException: Export utility returned with an exit code of: 101 with stdout: Loading ExportTool...
Missing svpip
and stderr: null