EMC ECS data source fails performance collections in OnCommand Insight or Cloud Insights, with error: "Request failed with status 500"
Applies to
- OnCommand Insight (OCI) 7.3
- Cloud Insights (CI)
- EMC ECS 3.5+ Data Source
Issue
- Performance collections on an EMC ECS data source in OCI or CI are failing with the following error:
Request failed with status 500
- Review of the data source recording shows an error similar to the following in the sample log:
Caused by: com.onaro.sanscreen.acquisition.util.stream.http.JsonRestResponseException: Request failed with status 500 : https://{STORAGE_ADDRESS}:4443/flux/api/external/v2/query
- Further review of the recording .dat file shows additional error context within the response payload:
{"error":"failed to compile query: validation failed: range 2h0m0s (start: 2022-03-08T17:41:11Z; stop: 2022-03-08T19:41:11Z) is longer than allowed 1 hour"}