Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 14 results
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_fix_a_mirror_degraded_system
      Applies to MetroCluster ONTAP 9 ONTAP 8 SyncMirror degraded Description Mirror degraded indicates that an aggregate that was configured as a mirrored aggregate is not mirrored any more. This article d...Applies to MetroCluster ONTAP 9 ONTAP 8 SyncMirror degraded Description Mirror degraded indicates that an aggregate that was configured as a mirrored aggregate is not mirrored any more. This article describes the procedure to be followed to fix a mirror degraded system.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Health_Monitor_process_schm__StorageBridgePowerSupplyFailed_Alert_AutoSupport_message
      Applies to MetroCluster Health Monitoring (ATTO Bridges) Answer This alert is triggered when MetroCluster Health Monitor detects a power supply failure on an ATTO Bridge. The failed PSU should be repl...Applies to MetroCluster Health Monitoring (ATTO Bridges) Answer This alert is triggered when MetroCluster Health Monitor detects a power supply failure on an ATTO Bridge. The failed PSU should be replace. Wed Nov 17 21:25:38 CST [node01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePowerSupplyFailed_Alert[200000xxxxxxxxxx/11/B]. Additional Information One of the power supplies(PSU) of ATTO 7500N/7600N FibreBridge is not online
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/LUNs_or_NFS_mount_not_accessible_after_DR_Operation_MCC_SwitchOver_Back
      Applies to MetroCluster ONTAP 9 Switchover on disaster Issue After a switchover -force-on-disaster true (USO) event: Servers lose connectivity to NFS mounts and need to be remounted. LUNs are offline
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/SHUTDOWN_PENDING_degraded_mode_AutoSupport_message
      The system enters RAID degraded mode and shows SHUTDOWN PENDING CRITICAL message.
    • https://kb.netapp.com/on-prem/Switches/NetApp-KBs/How_to_reset_password_on_CN1610_running_FASTPATH_1.2.0.7_or_later
      Applies to CN1610 FASTPATH 1.2.0.7 or later Description Prior to FASTPATH 1.2.0.7, one will have to perform a factory reset on a CN1610 if the administrator password had been lost. Starting with FASTP...Applies to CN1610 FASTPATH 1.2.0.7 or later Description Prior to FASTPATH 1.2.0.7, one will have to perform a factory reset on a CN1610 if the administrator password had been lost. Starting with FASTPATH 1.2.0.7, a new Password Recovery method is available, which does not require a factory reset.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/SwitchPowerFail_Alert_-_MetroCluster_switch_AutoSupport_Message
      MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. The FabricSwitchPowerFail_Alert indicates that one or more power ...MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. The FabricSwitchPowerFail_Alert indicates that one or more power supplies on the backend MetroCluster switches have reported an error. PowerSupply on switch is missing or is not operational.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_troubleshoot_MetroCluster_switch_health_monitoring
      Applies to MetroCluster ONTAP 9 Description Unable to monitor the status of MetroCluster backend switchesSwitch Health monitoring not working after switch upgrade (Temperature Sensors not collected)
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cable_attached_to_SAS_port_x_is_functioning_in_a_degraded_mode
      'Cable attached to SAS port x functioning in a degraded mode' messages are reported. There are few possible causes and this article helps in troubleshooting the issue.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/AutoSupport_Message__MetroCluster_switchover_complete
      Applies to MetroCluster ONTAP 9 Issue A MetroCluster Switchover operation has been initiated and completed successfully.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/What_is_the_procedure_for_graceful_shutdown_and_power_up_of_a_storage_system_during_scheduled_power_outage
      This article explains a series of procedures for different configurations: a) to gracefully shut down and power up your storage system during a scheduled power outage. b) the order to power elements u...This article explains a series of procedures for different configurations: a) to gracefully shut down and power up your storage system during a scheduled power outage. b) the order to power elements up and down during a power cycle procedure. c) to power off a storage system. Ensure backups and SnapMirror updates are completed before you start.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Overview_of_wafliron
      How to create a temporary volume for Wafliron status files How to run Wafliron on a non-root aggregate How to run Wafliron on a root aggregate or volume How to run Wafliron with Iron Optional Commit (...How to create a temporary volume for Wafliron status files How to run Wafliron on a non-root aggregate How to run Wafliron on a root aggregate or volume How to run Wafliron with Iron Optional Commit (IOC) How to run Wafliron on a SnapMirror or SnapVault volume Can Wafliron be run on a SnapLock aggregate or volume? Wafliron start failed with error The status files hosting volume could not be found How can you check the status of a Wafliron in ONTAP 7-mode