Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 10 results
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Not_all_the_ACP_firmwares_updated_for_shelves_with_IOM6
      Applies to IOM6 ACP firmware version 2.10 Issue Not all the ACP firmware are automatically updated in shelves with IOM6. The IOM6 modules are running different ACP fw. versions no hardware issues or e...Applies to IOM6 ACP firmware version 2.10 Issue Not all the ACP firmware are automatically updated in shelves with IOM6. The IOM6 modules are running different ACP fw. versions no hardware issues or errors being reported.
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/HCC_FW_upgrade_to_2_99_gets_stuck_when_already_upgraded_node_has_all_drives_Failed_Missing
      While the FW upgrade is still running, one of the already upgraded nodes suddenly fails all the drives out: If the failing node is sharing slices with the node that is currently upgraded (nodeMaintena...While the FW upgrade is still running, one of the already upgraded nodes suddenly fails all the drives out: If the failing node is sharing slices with the node that is currently upgraded (nodeMaintenanceMode), there is no possibility to sync the data Rebooting/power draining the failing node does not bring the drives back online Attempts to force the other node out of maintenance mode does not succeed: FailedToRecover Symlink on failing node is still showing the old package
    • https://kb.netapp.com/on-prem/E-Series/SANtricity-OS-KBs/Controller_firmware_download_failed
      Applies to E-Series Issue When attempting to upgrade controller firmware, the following message appears in the MEL on only one controller: 5025 Controller firmware download failed - Tray 99, Slot A or...Applies to E-Series Issue When attempting to upgrade controller firmware, the following message appears in the MEL on only one controller: 5025 Controller firmware download failed - Tray 99, Slot A or 5025 Controller firmware download failed - Tray 99, Slot B B:2/2/22, 1:14:50 PM (13:14:50) 331 5025 Controller firmware download failed - Shelf 99, Bay B B:2/2/22, 1:14:44 PM (13:14:44) 330 5009 Controller firmware download started - Shelf 99, Bay B - (08.52.00.01 -> 08.72.00.00)
    • https://kb.netapp.com/hybrid/StorageGRID/Maintenance/StorageGRID_node_reboot_loop_during_image_validation_after_redeployment
      After attempting to redeploy a StorageGRID node, the node enters a reboot loop during the PGE (Pre-GRID Environment) image validation step in the boot process. [2024-10-28 07:21:44+00:00 SGA] [root@St...After attempting to redeploy a StorageGRID node, the node enters a reboot loop during the PGE (Pre-GRID Environment) image validation step in the boot process. [2024-10-28 07:21:44+00:00 SGA] [root@StorageGRID-PGE:/mnt/pge-eos-lun/images] >>> sha1sum --check /mnt/pge-eos-lun/images/current-pge-image.bin.sha1 --status [2024-10-28 07:22:24+00:00 SGA] /mnt/pge-eos-lun/images/current-pge-image.bin.sha1 (3643bb47475756a536556465c675a84c7876e05b8a44a current-pge-image.bin) failed sha1sum --check
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Service_processor_password_doesn_t_update
      Applies to Cluster Data ONTAP 9.3 ONTAP 9 Service Processor Issue The service processor password does not update when the password is changed in the cluster shell.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Mellanox_switches_SSD_disk_firmware_update
      Applies to NVIDIA Mellanox Switches NVIDIA Mellanox Onyx Issue Mellanox SSD disks may go 'Read-Only' or system OS might get corrupted.
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/Cluster_Interconnect_delay_due_to_data_LIFs_not_local_to_node_owning_disks
      cluster1::> qos statistics volume latency show -iterations 100 Workload ID Latency Network Cluster Data Disk QoS NVRAM Cloud --------------- ------ -------- -------- -------- -------- -------- -------...cluster1::> qos statistics volume latency show -iterations 100 Workload ID Latency Network Cluster Data Disk QoS NVRAM Cloud --------------- ------ -------- -------- -------- -------- -------- -------- ---------- ---------- -total- 110.35ms 0ms 110.02ms 327.00us 0ms 0ms 0ms 0ms vs1vol0 111 167.82ms 0ms 167.22ms 603.00us 0ms 0ms 0ms 0ms vol1 1234 117.76ms 0ms 117.56ms 191.00us 0ms 0ms 0ms 0ms
    • https://kb.netapp.com/hybrid/StorageGRID/Object_Mgmt/StorageGRID_software_upgrade_resolution_guide
      This Resolution Guide provides an overview of known issues that might be encountered during StorageGRID software upgrades and, the related solutions to these known issues
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/IOM12E_firmware_upgrade_failed_in_MetroCluster_configuration
      IOM12E firmware is downloaded successfully to one cluster: cluster::> storage firmware download -node * -package-url http://web_server/IOM12E.0230.SFW.zip Firmware download started. Firmware downloade...IOM12E firmware is downloaded successfully to one cluster: cluster::> storage firmware download -node * -package-url http://web_server/IOM12E.0230.SFW.zip Firmware download started. Firmware downloaded. cluster::> storage shelf firmware update -module-type IOM12E Error: Shelf firmware update request failed because no eligible shelves found with module type "IOM12E" All modules on both cluster report old firmware version: cluster::> storage shelf show -fields module-fw-revision,module-type
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_upgrade_the_ATTO_FibreBridge_firmware_inband_without_HTTP_server
      Applies to ATTO 7500N FibreBridge ATTO 7600N FibreBridge ATTO FibreBridge In-band Firmware Upgrade MetroCluster FC No FTP / FTPS / HTTP / HTTPS server Description This article describes how to copy AT...Applies to ATTO 7500N FibreBridge ATTO 7600N FibreBridge ATTO FibreBridge In-band Firmware Upgrade MetroCluster FC No FTP / FTPS / HTTP / HTTPS server Description This article describes how to copy ATTO bridge firmware to controller when you don't have access to a Webserver via SCP from a Windows system then trigger the inband upgrade.