Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 7 results
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/diag_secd_cache_clear_command_no_longer_supports_cache_name_nis-group-membership
      Applies to ONTAP 9.11.1 Issue diag secd cache clear command no longer supports cache name nis-group-membership Example: cluster1::*> diag secd cache clear -node cluster1-01 -vserver svm1_cluster1 -cac...Applies to ONTAP 9.11.1 Issue diag secd cache clear command no longer supports cache name nis-group-membership Example: cluster1::*> diag secd cache clear -node cluster1-01 -vserver svm1_cluster1 -cache-name nis-group-membership Error: command failed: Operation not supported. Use commands available in "vserver services name-service nis-domain group-database" directory instead.
    • https://kb.netapp.com/Cloud/BlueXP/edge_caching/How_to_change_Cache_Purge_percentage_on_Global_File_Cache_GFC
      Applies to Global File Cache (GFC) Global File Cache Edge Description Changing the limit that the automatic purging of the GFC Edge cache begins when the used space reaches the limit.
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Unable_to_mount_NFS_shares_permission_denied
      Applies to ONTAP 9 Issue Mounting NFS shares from Linux servers are no longer possible, even though no changes were made from ONTAP side - Fails with access denied
    • https://kb.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/Active_IQ_Unified_Manager_redirects_to_Dashboard_screen_when_using_a_link_to_access_the_UI
      Applies to Active IQ Unified Manager (AIQUM) 9.9P1+ Issue After upgrading UM, attempting to use a link for a storage object (e.g. in an alert email) results in a redirect to the UM dashboard. Clicking...Applies to Active IQ Unified Manager (AIQUM) 9.9P1+ Issue After upgrading UM, attempting to use a link for a storage object (e.g. in an alert email) results in a redirect to the UM dashboard. Clicking any link within the UM web UI redirects to the UM dashboard A link to any object within UM will produce this effect. E.g. volume, SVM, LUN, cluster, etc. Incognito or inPrivate mode works fine
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Flash_Cache_is_stuck_in_rewarming_phase_and_does_not_accept_insertions
      Flash Cache is stuck in rewarming phase and does not accept insertions with the following symptoms: Low cache insert/hit rate in Flash Cache To confirm the low cache insert/hit rate in Flash Cache: cl...Flash Cache is stuck in rewarming phase and does not accept insertions with the following symptoms: Low cache insert/hit rate in Flash Cache To confirm the low cache insert/hit rate in Flash Cache: cluster::*> statistics start -sample-id <test1> -object ext_cache_obj -counter inserts|hit_percent|rewarm_aggrs_failed Statistics collection is being started for sample-id: test1 inserts should be lower than 10/s, indicating no data is being inserted into Flash Cache
    • https://kb.netapp.com/on-prem/ontap/DM/System_Manager/SM-KBs/Can_Flash_Cache_performance_be_monitored_in_the_redesigned_System_Manager_9_8_interface
      Applies to ONTAP System Manager 9.8+ Answer Flash Cache / Hardware Cache performance cannot be monitored via System Manager 9.8+, as this feature is removed from the redesigned web interface. Addition...Applies to ONTAP System Manager 9.8+ Answer Flash Cache / Hardware Cache performance cannot be monitored via System Manager 9.8+, as this feature is removed from the redesigned web interface. Additional Information additionalInformation_text
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cannot_access_CIFS_share_and_show_error_path_not_found
      Applies to ONTAP 9 CIFS/SMB Issue Client cannot access CIFS share(s) and shows the error: path not found.