Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 5 results
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/disconnectedClusterPair_alert_on_Element_cluster
      Applies to NetApp Element software NetApp HCI NetApp SolidFire Issue The Element cluster UI (https://<MVIP>) and SolidFire Active IQ show the following alert: Alert Type: disconnectedClusterPair Detai...Applies to NetApp Element software NetApp HCI NetApp SolidFire Issue The Element cluster UI (https://<MVIP>) and SolidFire Active IQ show the following alert: Alert Type: disconnectedClusterPair Details: One of the clusters in a pair may have become misconfigured or disconnected. Remove the local pairing and retry pairing the clusters. Disconnected Cluster Pairs: [x]. Misconfigured Cluster Pairs
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__VASA_provider_certificate_expiration_alarm
      Applies to NetApp HCI VMware vCenter 6.x or 7.x VMware ESXi 6.x or 7.x vSphere 6.x or 7.x Issue Host VASA provider certificate expiration alarm reported in NetApp SolidFire Active IQ: Alert name: VASA...Applies to NetApp HCI VMware vCenter 6.x or 7.x VMware ESXi 6.x or 7.x vSphere 6.x or 7.x Issue Host VASA provider certificate expiration alarm reported in NetApp SolidFire Active IQ: Alert name: VASA provider certificate expiration alarm Description: Monitors whether VASA provider certificates are getting close to their expiry date
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_migrate_SolidFire_vCenter_API_for_Storage_Awareness_VASA_from_one_vSphere_instance_to_another
      When attempting to migrate to a new vCenter, VASA may issues with the old vCenter keystore being persistent, leading to inaccessible VVol containers and a data unavailable situation. The SolidFire VAS...When attempting to migrate to a new vCenter, VASA may issues with the old vCenter keystore being persistent, leading to inaccessible VVol containers and a data unavailable situation. The SolidFire VASA provider can only be registered to a single vCenter due to limitations with how vCenter handles SSL. A single vCenter can have multiple SolidFire clusters, but a SolidFire cluster cannot be shared between two instance of vCenter.
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/failedSpaceTooFull_error_alert_during_Element_software_upgrade
      NetApp SolidFire Storage Nodes NetApp H Series Storage Nodes NetApp Element software 12.3 and higher The following error is shown on NetApp SolidFire Active IQ for some nodes during an Element softwar...NetApp SolidFire Storage Nodes NetApp H Series Storage Nodes NetApp Element software 12.3 and higher The following error is shown on NetApp SolidFire Active IQ for some nodes during an Element software upgrade or during an automatic RTFI process during a NetApp storage node replacement. Error Code: failedSpaceTooFull Details: Slice service is using 25% of the space reserved for failed writes. The error is resolved soon after the node completes the upgrade
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_forward_syslog_messages_to_a_remote_host
      Applies to NetApp Element Software NetApp SolidFire NetApp HCI Description Enable remote syslog forwarding from the storage nodes to a remote server