    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/HCC_cannot_access_repositories_after_mNode_reboot
      Applies to NetApp Hybrid Cloud Control (HCC) Management node (mNode) Proxy configured Issue After a reboot of the mNode HCC shows the message: We are unable to access online NetApp repositories. For a...Applies to NetApp Hybrid Cloud Control (HCC) Management node (mNode) Proxy configured Issue After a reboot of the mNode HCC shows the message: We are unable to access online NetApp repositories. For an enhanced Hybrid Cloud Control, ensure your management node has a connection to access online NetApp repositories.
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Correctable_ECC_memory_error_count_crossed_threshold_on_Memory_controller
      Applies to NetApp Element software 12.0 and above NetApp SolidFire SF-Series node NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Error code: memoryEccThreshold Details: Correctable ECC mem...Applies to NetApp Element software 12.0 and above NetApp SolidFire SF-Series node NetApp H-series Issue Alert in NetApp SolidFire Active IQ: Error code: memoryEccThreshold Details: Correctable ECC memory error count crossed threshold on Memory controller: MemCtlr<#> SNMP alert: ECC RAM error: <#> Memory Error Memory Parity Error(<CPU_bank>) - Asserted BMC system event list (SEL): Memory <#> | Parity | Asserted or Memory <#> | Correctable ECC | Asserted
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/MLAG_on_Mellanox_switch_reports_Failed_to_grow_the_pool_size_err_-12
      Some virtual machines(VMs) are not able to be pinged or reached from devices within same LAN or connect to external network. When these occurs, there may be associated errors in the switch logs (as ge...Some virtual machines(VMs) are not able to be pinged or reached from devices within same LAN or connect to external network. When these occurs, there may be associated errors in the switch logs (as generated by sysdump) along these lines: HCI-MLX2 mlagd[4799]: TID 140503404242688: [mlagd.NOTICE]: [MLAG_MAC_SYNC_PEER_MANAGER.NOTICE] Failed to grow the pool size, err -12
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Citrix_pool_master_timeout_on_heartbeat_volume_during_slice_migration
      slice82[57705]: [UNCERR-3] [SCSIDevice] 22949 TSSocket-81 iscsitarget/SCSITask.cpp:664:Abort|srcid=3794 reqid=553648144 EIO-WARNING: cMaxSCSITaskLatencyAbortEventLimitMSec=20000 SCSITask: tag=18454937...slice82[57705]: [UNCERR-3] [SCSIDevice] 22949 TSSocket-81 iscsitarget/SCSITask.cpp:664:Abort|srcid=3794 reqid=553648144 EIO-WARNING: cMaxSCSITaskLatencyAbortEventLimitMSec=20000 SCSITask: tag=1845493776 sessionID=347892354770 volumeID=160 RawLUN=0x0 generation=0xf0cdd9e896c498e8 mTaskState=Enabled mCommandType=Write mVolumeBlockSize=512 mExpectedTransferLength=65536 mSCSITransferLength=65536 mActualTransferLength=65536 mScsiStatus=0xff mAborted=1 mAbortCompleted=0 mAbortReason=InitiatorSentAbor…