Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 38 results
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCE_schedules_not_triggered_post_upgrade_of_SnapCenter_server
      Applies to SnapCenter server SnapCenter Plug-in for Exchange (SCE) Issue After upgrade of SnapCenter server, schedules for SCE with older plug-in version not triggered anymore SnapManagerWeb will have...Applies to SnapCenter server SnapCenter Plug-in for Exchange (SCE) Issue After upgrade of SnapCenter server, schedules for SCE with older plug-in version not triggered anymore SnapManagerWeb will have the following error: ErrorCode (136), ErrorMessage (The user you are trying does not have permission to access the system. Please re-authenticate to continue or contact your administrator.)
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SnapCenter_fails_to_enumerate_disks_for_a_Windows_host_or_cluster
      Applies to SnapCenter Server Issue No disks are enumerated in the SnapCenter UI for a host(s) or Windows Cluster
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCW_doesn_t_show_part_of_the_disks
      Applies to SnapCenter Server (SC) SnapCenter Plug-in for Windows (SCW) Issue SnapCenter doesn't detect part of the disks for server
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCE_-_vss_e_provider_veto_-_volumes_are_too_full_to_create_SnapShots
      SCE backups fail with the error message - Error1:Failed to create VSS snapshot [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] Possible solution: Please...SCE backups fail with the error message - Error1:Failed to create VSS snapshot [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] Possible solution: Please check if there is adequete space available on the LUNs. The below error will be seen on the storage system: Error2: scsiblade.lun.offline.system: LUN 80xxxxxx in volume with MSID 21xxxxx on Vserver svm1 has been brought offline due to lack of space in the volume.
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SnapCenter_Plugin_for_Exchange_backup_fails_with_VSS_E_UNEXPECTED_PROVIDER_ERROR
      Applies to SnapCenter (SC) SnapCenter Plug-in for Exchange (SCE) SnapCenter Plug-in for Windows (SCW) Issue SnapCenter Plugin for Exchange backup fails with a error VSS_E_UNEXPECTED_PROVIDER_ERROR or ...Applies to SnapCenter (SC) SnapCenter Plug-in for Exchange (SCE) SnapCenter Plug-in for Windows (SCW) Issue SnapCenter Plugin for Exchange backup fails with a error VSS_E_UNEXPECTED_PROVIDER_ERROR or VSS_E_SNAPSHOT_SET_IN_PROGRESS
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCE_VSS_E_UNEXPECTED_PROVIDER_ERROR_errors
      SnapCenter Plug-In for Exchange (SCE) hub article for VSS_E_UNEXPECTED_PROVIDER_ERROR errors
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/Snap_Center_Resource_discovery_job_hangs
      After successful plugin installation the resource discovery job hangs as running SnapManagerWeb<Job ID>.log shows that a Resource discovery request is sent to the plugin and the log ends. System.Net.W...After successful plugin installation the resource discovery job hangs as running SnapManagerWeb<Job ID>.log shows that a Resource discovery request is sent to the plugin and the log ends. System.Net.WebException: Unable to connect to the remote server ---> System.Net.Sockets.SocketException: A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond <SC Server IP>:8146
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SnapCenter_Plug-In_for_Exchange_backup_fails_when_Reserved_partition_is_missing
      2019-05-15T04:00:26.2759880-04:00 Error SCE PID=[2412] TID=[7980] Failed to create VSS snapshot [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] 2019-05-15T04:00:26.2969885-04:00 Error SCE PID=[2412] T...2019-05-15T04:00:26.2759880-04:00 Error SCE PID=[2412] TID=[7980] Failed to create VSS snapshot [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] 2019-05-15T04:00:26.2969885-04:00 Error SCE PID=[2412] TID=[7980] Failed to create VSS snapshot [Error Code: -2147212538] [VSS_E_PROVIDER_VETO] [Error Code: -2147212538] [VSS_E_PROVIDER_VETO]
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCE_installation_fails_on_a_standalone_Exchange_server
      Applies to SnapCenter Server (SC) 4 SnapCenter Plug-in for Microsoft Exchange Server (SCE) 4 Microsoft Exchange Server (Standalone) Issue SCE installation fails on a Exchange server Error message: Fai...Applies to SnapCenter Server (SC) 4 SnapCenter Plug-in for Microsoft Exchange Server (SCE) 4 Microsoft Exchange Server (Standalone) Issue SCE installation fails on a Exchange server Error message: Failed to release Mutex object, Error: Object synchronization method was called from an unsynchronized block of code.
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCE_Backup_fails_with_VSS_E_OBJECT_ALREADY_EXISTS
      Applies to SnapManager for Exchange Plug-in (SCE) 4.3.1 Microsoft Exchange Issue Backup of resource group with Exchange Databases fails with error: Failed to add database to backup components [DB: DB2...Applies to SnapManager for Exchange Plug-in (SCE) 4.3.1 Microsoft Exchange Issue Backup of resource group with Exchange Databases fails with error: Failed to add database to backup components [DB: DB2, Instance: server2] [Error Code: -2147212531] [VSS_E_OBJECT_ALREADY_EXISTS]
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SnapCenter_Plugin_for_Exchange_backup_fails_with_VSS_E_UNEXPECTED_PROVIDER_ERROR_on_first_backup_attempts
      Applies to SnapCenter Plug-In for Exchange (SCE) SnapCenter Plug-in for Microsoft Windows Server (SCW) Issue SnapCenter Plugin for Exchange backup fails with an error VSS_E_UNEXPECTED_PROVIDER_ERROR A...Applies to SnapCenter Plug-In for Exchange (SCE) SnapCenter Plug-in for Microsoft Windows Server (SCW) Issue SnapCenter Plugin for Exchange backup fails with an error VSS_E_UNEXPECTED_PROVIDER_ERROR Alternatively, may have the error VSS_E_PROVIDER_NOT_REGISTERED Also affects up to the minute (UTM) retention as this is skipped, as seen in the failed Job Details