Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 2 results
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/Cisco_3132Q-V_RCF_1.6_causes_TCAM_region_is_not_configured_error_and_blocks_10GbE_connectivity
      Applies to Cisco Nexus 3132Q-V RCF 1.6 Issue RCF 1.6 installation issue: 2021 Mar 18 16:35:19 NetApp_CLS_SW-A %$ VDC-1 %$ %ACLQOS-SLOT1-2-ACLQOS_FAILED: ACLQOS failure: TCAM region is not configured f...Applies to Cisco Nexus 3132Q-V RCF 1.6 Issue RCF 1.6 installation issue: 2021 Mar 18 16:35:19 NetApp_CLS_SW-A %$ VDC-1 %$ %ACLQOS-SLOT1-2-ACLQOS_FAILED: ACLQOS failure: TCAM region is not configured for feature QoS class IPv4 direction ingress. Please configure TCAM region IPV4 Port QoS [qos] and retry the command. While attempting to utilize the 10GbE breakout ports, the cluster ports are non-functional
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/ror_in_configuration_script_file_at_line_number_XX_when_applying_a_new_RCF
      Error applying a new RCF file to a Broadcom BES-53248. (CS1) #script apply BES-53248_RCF_v1.6-Cluster-HA.scr Are you sure you want to apply the configuration script? (y/n) y config ... match cos 5 Unr...Error applying a new RCF file to a Broadcom BES-53248. (CS1) #script apply BES-53248_RCF_v1.6-Cluster-HA.scr Are you sure you want to apply the configuration script? (y/n) y config ... match cos 5 Unrecognized command : match cos 5 Error! in configuration script file at line number 40. Execution of configuration script 'BES-53248_RCF_v1.6-Cluster-HA.scr' could not be completed. WARNING: The running configuration may not be the desired configuration.