Issue In the system-level diagnostics version 07.02.03 and 07.02.04 with BMC version 18.2 and later, the fan test will fail on the below platforms. AFF A1K AFF A90 AFF A70 Example: Set Sysfan3_F1_Spee...Issue In the system-level diagnostics version 07.02.03 and 07.02.04 with BMC version 18.2 and later, the fan test will fail on the below platforms. AFF A1K AFF A90 AFF A70 Example: Set Sysfan3_F1_Speed to 80% Duty cycle Check RPM in the range from 17328 to 19152 RPM Getting fan speed Getting fan speed Getting fan speed Sysfan3_F1_Speed expect in range from 17328 to 19152 RPM, current 21450 RPM, result: FAIL