Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 5 results
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/Link_break_on_FCoE__Firmware_status_code_status1_0x10_status2_0x7_and_status4_0x31
      Applies to ONTAP 9.X Issue FCoE LIF shows Extended Status: waiting for Link. Link break detected with the following EMS message: [NETAPP01: fct_tpd_work_thread_0: scsitarget.ispfct.linkBreak:error]: L...Applies to ONTAP 9.X Issue FCoE LIF shows Extended Status: waiting for Link. Link break detected with the following EMS message: [NETAPP01: fct_tpd_work_thread_0: scsitarget.ispfct.linkBreak:error]: Link break detected on Fibre Channel target adapter 2a. Firmware status code status1 0x10, status2 0x7, and status4 0x31.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/FCoE_ports_no_longer_show_as_up_on_any_ports_in_the_environment_in_ONTAP
      Applies to ONTAP 9.X FCoE Issue Host were no longer able to see their boot LUN due to all FCoE connections were down
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Controller_panic_and_CNA_ports_down_when_connecting_to_Cisco_Nexus_Fabric_Extender
      When connecting Qlogic adapters to a Nexus FEX, the storage node panics PANIC : PCI Error NMI from device(s):RPT(0,3,3):QLogic FC/10GbE CNA on Controller. PCI Error NMI from device(s):ErrSrcID(CorrSrc...When connecting Qlogic adapters to a Nexus FEX, the storage node panics PANIC : PCI Error NMI from device(s):RPT(0,3,3):QLogic FC/10GbE CNA on Controller. PCI Error NMI from device(s):ErrSrcID(CorrSrc(0x2900),UCorrSrc(0)), RPT(0,2,0):QLogic FC/10GbE CNA in slot 2 on Controller. After the storage node boots from panic, the CNA ports are stuck in initalizing firmware state This can be triggered when the Cisco switch is upgraded to version 9.3(5) or later.
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/SolidFire_SF_series_nodes_send_Erroneous_LLDP_packets_impacting_Network_device_SSD_lifespan
      Applies to SolidFire SF series Nodes Issue Erroneous LLDP packets to network devices from SolidFire SF series Nodes is reducing the lifespan of network device SSD.
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Device_information_present_in_network_device-discovery_output_after_lldp_is_disabled
      Applies to ONTAP 9.7+ Answer Default behavior, with lldp.enable off, is receiving LLDP information is enabled on all ports, while transmit is enabled for Cluster, Storage and HA ports. Additional Info...Applies to ONTAP 9.7+ Answer Default behavior, with lldp.enable off, is receiving LLDP information is enabled on all ports, while transmit is enabled for Cluster, Storage and HA ports. Additional Information