Applies to ONTAP 9 Answer It is normal. Disk LED is managed by ONTAP. When disk is missing, ONTAP will not manage it, so LED is green sometimes. Additional Information additionalInformation_text
Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) ha...Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) has not been cleared, the warning LEDs will remain activated. This article will describe how to clear the SEL from BMC/IPMI. Note: Not all LED errors can be resolved by clearing the SEL. Refer Additional Information for further steps/investigation that may be required.
Applies to AFF-A800/C800, AFF-A250/C250 NVMe internal shelf Issue Disk fault LED is still lit even after failed disk has been replaced Issuing the LED off command turns it off for a period of time but...Applies to AFF-A800/C800, AFF-A250/C250 NVMe internal shelf Issue Disk fault LED is still lit even after failed disk has been replaced Issuing the LED off command turns it off for a period of time but it comes back on
Applies to NetApp E-Series E2824 NetApp SANtricity OS 11.60.x Issue After multiple disk failure, replacement and recovery several disk bays have error ( Orange) LED lit No errors detected in logs
Applies to DS212-12 DS2246 DS460C NS224 Issue Attention LED ON in the OPS Panel of the shelf. No alerts/warnings/etc. being reported in the EMS logs. In some cases, some activity was done in the shelf...Applies to DS212-12 DS2246 DS460C NS224 Issue Attention LED ON in the OPS Panel of the shelf. No alerts/warnings/etc. being reported in the EMS logs. In some cases, some activity was done in the shelf (example: Power Supply Unit or IOM replaced/re-seated)
::> system controller service-event show -instance Node: NODE_NAME Service Event ID: 1 Location: NVDIMM 1 on PCI 6 Description: NVDIMM1:UECC detected Timestamp: Wed May 30 12:20:03 2018 Node: NODE_NAM...::> system controller service-event show -instance Node: NODE_NAME Service Event ID: 1 Location: NVDIMM 1 on PCI 6 Description: NVDIMM1:UECC detected Timestamp: Wed May 30 12:20:03 2018 Node: NODE_NAME Service Event ID:2 Location: NVDIMM 2 on PCI6 Description: NVDIMM2: UECC detected Timestamp: Wed May 30 12:20:04 2018 2 entries were displayed. Please replace it as soon as possible!!! *************************** WARNING: The NVRAM DIMM2 has caused UECC in the past.