Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 6 results
    • https://kb.netapp.com/Cloud/Cloud_Volumes_ONTAP/How_to_Ping_in_NetApp_Cloud_Volumes_ONTAP_for_Azure
      Applies to NetApp Cloud Volumes ONTAP for Azure Description According to Microsoft's Azure documentation, the ICMP protocol is not permitted through the Azure load balancer, which will cause network p...Applies to NetApp Cloud Volumes ONTAP for Azure Description According to Microsoft's Azure documentation, the ICMP protocol is not permitted through the Azure load balancer, which will cause network pings to fail.
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Download_of_firmware_image_fails_in_ONTAP_however_download_succeeds_with_node_at_LOADER
      Downloading a new ONTAP image or firmware file fails once a node boots up ONTAP, however it works as expected when downloading from the HTTP server at the LOADER prompt (prior to booting ONTAP on the ...Downloading a new ONTAP image or firmware file fails once a node boots up ONTAP, however it works as expected when downloading from the HTTP server at the LOADER prompt (prior to booting ONTAP on the node) NetApp Data ONTAP 9.5P12 <<<---ONTAP is booting here This procedure will replace existing Data ONTAP software with new software. What is the URL for the package? Verify that the network is properly configured, that the gateway is set
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/Ping_loss_towards_out-of-band_interface_on_Element
      Applies to NetApp SolidFire SF-Series (all models starting with SF) Not applicable to NetApp H-series Out-of-band interface (BMC/iDRAC) Firmware revision of the iDRAC is 1.57.57 Issue SNMP tools are r...Applies to NetApp SolidFire SF-Series (all models starting with SF) Not applicable to NetApp H-series Out-of-band interface (BMC/iDRAC) Firmware revision of the iDRAC is 1.57.57 Issue SNMP tools are reporting intermittent ping drops towards the out-of-band interface Manual ping tests towards the out-of-band interface are showing drops
    • https://kb.netapp.com/on-prem/ontap/DP/SnapMirror/SnapMirror-KBs/Cannot_establish_cluster_peering_Data_connection_but_ICMP_is_working
      [?] Mon Mar 28 00:36:28 +0300 [<cluster_name-02>: mgwd: cpeer.xcm.addr.disc.warn:error]: Address discovery failed for peer cluster <UUID>. Reason: Failed to discover remote addresses: Failed to contac...[?] Mon Mar 28 00:36:28 +0300 [<cluster_name-02>: mgwd: cpeer.xcm.addr.disc.warn:error]: Address discovery failed for peer cluster <UUID>. Reason: Failed to discover remote addresses: Failed to contact peer cluster "<cluster_name>" at addresses: <IP>. RPC: Remote system error [from mgwd on node "<cluster_name-02>" (VSID: -3) to mgwd at <IP>].
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/ICMP_ping_responses_from_storage_system_occasionally_delay
      Applies to ONTAP 9 Issue ICMP ping responses from storage system occasionally delay Example: ip.addr == CLIENT_IP and ip.addr == STORAGE_IP 971 2022-11-10 17:36:29.125758 CLIENT_IP STORAGE_IP ICMP Ech...Applies to ONTAP 9 Issue ICMP ping responses from storage system occasionally delay Example: ip.addr == CLIENT_IP and ip.addr == STORAGE_IP 971 2022-11-10 17:36:29.125758 CLIENT_IP STORAGE_IP ICMP Echo (ping) request id=0x0001, seq=6580/46105, ttl=125 (reply in 973) 973 2022-11-10 17:36:29.457171 STORAGE_IP CLIENT_IP ICMP Echo (ping) reply id=0x0001, seq=6580/46105, ttl=64 (request in 971) Note: The packet trace is captured from storage system
    • https://kb.netapp.com/hybrid/StorageGRID/Grid_Tenant_Manager/CVE-1999-0524_ICMP_Timestamp_Request_Remote_Date_Disclosure
      Applies to StorageGRID BMC Tenable Nessus Common Vulnerabilities and Exposures (CVE) Issue When running a vulnerability scan, the scan can pick up CVE-1999-0524 against the BMC for a SG6000 or SG1000/...Applies to StorageGRID BMC Tenable Nessus Common Vulnerabilities and Exposures (CVE) Issue When running a vulnerability scan, the scan can pick up CVE-1999-0524 against the BMC for a SG6000 or SG1000/100 compute node.