    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/PSOD_with_Internal_Parity_Error_on_H410C
      Applies to NetApp H410C Purple screen of death (PSOD) BIOS version NA3.4 and lower Issue Compute node has PSOD with the following line: cpu53:32856290MCA: 130 UC Excp G5 B2 Sb200000000020005 A0 M0 P0/...Applies to NetApp H410C Purple screen of death (PSOD) BIOS version NA3.4 and lower Issue Compute node has PSOD with the following line: cpu53:32856290MCA: 130 UC Excp G5 B2 Sb200000000020005 A0 M0 P0/0 Internal Parity Error
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/How_to_regenerate_self-signed_certificate_of_IPMI
      Applies to Intelligent Platform Management Interface (IPMI) Description Regenerating an expired self-signed certificate of Intelligent Platform Management Interface (IPMI)
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Which_serial_console_cable_can_be_used_for_HCI_SF_products
      Applies to NetApp H-series nodes NetApp SolidFire SF-Series nodes Answer SolidFire SF-Series and H-series nodes nodes do not support any functionality through a node’s RS-232 serial port and don’t hav...Applies to NetApp H-series nodes NetApp SolidFire SF-Series nodes Answer SolidFire SF-Series and H-series nodes nodes do not support any functionality through a node’s RS-232 serial port and don’t have serial consoles like the other products do. So no serial consoles cables are available for these models. Onboard VGA port for a monitor and USB port for a keyboard can be used for deployment purposes. Additional Information additionalInformation_text
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/Compute_Node_Reporting_Predictive_Failure_-_VIN_UV_WARNING_on_PSU
      Applies to NetApp SolidFire SF-Series node NetApp H-series Issue A VMware vSphere alarm and the IPMI/BMC Event Logs are messages: [Information] [Device_Name_Status] [Device_Name] Predictive Failure - ...Applies to NetApp SolidFire SF-Series node NetApp H-series Issue A VMware vSphere alarm and the IPMI/BMC Event Logs are messages: [Information] [Device_Name_Status] [Device_Name] Predictive Failure - VIN_UV_WARNING - Asserted [Critical] [Device_Name_Status] [Device_Name] Device_Name Failure Detected - Output Overcurrent Fault - Asserted [Warning] [Device_Name_Status] [Device_Name] Predictive Failure - IOUT_OC_WARNING - Asserted
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/VMWare_ESXi_reports_Lost_path_redundancy_and_node_turns_unresponsive_node
      Applies to NetApp H-Series VMware ESXi Issue ESXi reports Lost path redundancy to storage device and node becomes unresponsive Path vmhba64:C1:T0:L0 is down. Affected datastores: Datastore-01. Lost pa...Applies to NetApp H-Series VMware ESXi Issue ESXi reports Lost path redundancy to storage device and node becomes unresponsive Path vmhba64:C1:T0:L0 is down. Affected datastores: Datastore-01. Lost path redundancy to storage device naa.6a89bdd20000000068246f770000002. Path vmhba64:C1:T1:L0 is down. Affected datastores: Datastore-02.
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/ISOLINUX__error_message_when_mounting_an_ISO_from_BMC
      Applies to NetApp H615C Issue When mounting an ISO image from BMC and rebooting the host the following error is displayed - ISOLINUX 6.04 6.04-pre1 ETCDisolinux: Disk error 31, AX = 422E, drive EF
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/NetApp_H-series_IPMI_SSH_security_vulnerability
      Applies to NetApp H-series Intelligent Platform Management [Interface] (IPMI) Secure Shell (SSH) Issue Running a security scan against Hxxx node's IPMI reports weak SSH weaknesses SSH Weak MAC Algorit...Applies to NetApp H-series Intelligent Platform Management [Interface] (IPMI) Secure Shell (SSH) Issue Running a security scan against Hxxx node's IPMI reports weak SSH weaknesses SSH Weak MAC Algorithms Enabled SSH Server CBC Mode Ciphers Enabled
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Credentials_not_accepted_on_BMC_UI_login_screen_for_H610S
      Applies to NetApp H610S NetApp Element software 11.7 Issue Credentials not accepted on BMC UI login screen No error messages appearing After confirming the credentials a "Processing" message appears a...Applies to NetApp H610S NetApp Element software 11.7 Issue Credentials not accepted on BMC UI login screen No error messages appearing After confirming the credentials a "Processing" message appears and then returns to the login screen with blank fields The reset password option is not available wget/curl no-certificate working on port 80/443 netcat (nc -zvw5) on port 22/80/443 not working: Connection refused
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Sensors_are_not_detected_in_IPMI_BMC_after_chassis_shutdown
      Sensors are not detected in IPMI/BMC after chassis shutdown 610079 2022-01-24 11:19:37 platformHardwareEvent Hardware fault detected - 4 - "Hardware fault ID <X> 610078 2022-01-24 11:19:37 platformHar...Sensors are not detected in IPMI/BMC after chassis shutdown 610079 2022-01-24 11:19:37 platformHardwareEvent Hardware fault detected - 4 - "Hardware fault ID <X> 610078 2022-01-24 11:19:37 platformHardwareEvent Hardware fault detected - 4 - "Hardware fault ID <Y> 610080 2022-01-24 11:20:10 platformHardwareEvent Hardware fault resolved - 4 - "Hardware fault ID <X>" 610082 2022-01-24 11:20:10 platformHardwareEvent Hardware fault resolved - 4 - "Hardware fault ID <Y>"
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Failed_to_send_messages_between_nodes_using_the_maximum_configured_MTU_9000
      Applies to Element software No Configuration issue on SF Storage Nodes and switch Issue Flapping alerts in Active IQ, solved in a short period of time: Failed to send messages between nodes using the ...Applies to Element software No Configuration issue on SF Storage Nodes and switch Issue Flapping alerts in Active IQ, solved in a short period of time: Failed to send messages between nodes using the maximum configured MTU (9000). Messages between the following nodes failed: {}. Incorrect MTU settings can prevent garbage collection from running and cause performance problems.