Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 6 results
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Error_when_running_commands_on_Brocade_FC_switch__fabos_not_yet_initialized
      Applies to Brocade FC switches without replaceable blades Issue Running commands on the Fabric OS command line of a Brocade FC (Fibre Channel) switch produces an error like the following: Example: Bro...Applies to Brocade FC switches without replaceable blades Issue Running commands on the Fabric OS command line of a Brocade FC (Fibre Channel) switch produces an error like the following: Example: Brocade6505:admin> version Brocade6505:admin> reboot Brocade6505:admin> uptime Brocade6505:admin> fastboot Brocade6505:admin> errdump fabos not yet initialized: -1
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Brocade_switch_has_constant_SEC_TELNET_violations_messages
      Applies to Brocade FABOS Brocade SANNAV Issue Switch is reporting telnet violations [MAPS-1003], 21222, SLOT 1 | FID 128, WARNING, brocade01, Switch, Condition=SWITCH(SEC_TELNET/min>2), Current Value:...Applies to Brocade FABOS Brocade SANNAV Issue Switch is reporting telnet violations [MAPS-1003], 21222, SLOT 1 | FID 128, WARNING, brocade01, Switch, Condition=SWITCH(SEC_TELNET/min>2), Current Value:[SEC_TELNET, 4 Violations], RuleName=rule1 Dashboard Category=Security Violations.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Rename_or_copy_the_zone_object_configuration_of_a_Brocade_Switch
      Applies to Brocade FOS 7.4.X Brocade FOS 8.X.X Description How to rename or copy the zone object configuration of a Brocade Switch.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Brocade_Switch_boots_in_runlevel_2_and_will_not_any_accept_commands_via_CLI
      Applies to Brocade FABOS 8.X No command will run in CLI after login has occurred Switch shows runlevel: 2 at boot BootROM version: 3.0.32 Copyright (C) 2017 Brocade Communication. CPU0: T1022E, Versio...Applies to Brocade FABOS 8.X No command will run in CLI after login has occurred Switch shows runlevel: 2 at boot BootROM version: 3.0.32 Copyright (C) 2017 Brocade Communication. CPU0: T1022E, Version: 1.1, (0x85290211) Core: e5500, Version: 2.1, (0x80241021) Single Source Clock Configuration Bypassing firmware validation. root=/dev/sda1 rootfstype=ext4 console=ttyS0,9600 rootdelay=5 pcie_ports=native quiet 2 ########Installing SWBD162 libhil INIT: Entering runlevel: 2
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/How_to_review_security_vulnerabilities_for_Brocade_products
      Applies to Brocade Description Brocade publishes a list of latest common vulnerabilities and exposures (CVE) in their Brocade Security Advisories website, which may or may not be affecting their curre...Applies to Brocade Description Brocade publishes a list of latest common vulnerabilities and exposures (CVE) in their Brocade Security Advisories website, which may or may not be affecting their current line of products.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Port_marked_as_Slow_Drain_Device_in_Brocade_switch
      A port or ports are marked as a 'Slow Drain Device' in the Brocade switch, verified by running sddquarantine --show 2020/06/04-09:25:22, [MAPS-1022], 74058, SLOT 7 | FID 128, WARNING, SANCORESWITCH, P...A port or ports are marked as a 'Slow Drain Device' in the Brocade switch, verified by running sddquarantine --show 2020/06/04-09:25:22, [MAPS-1022], 74058, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) has been marked as Slow Drain Device. 2020/06/04-09:36:22, [MAPS-1025], 74062, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) removed from the Slow Drain Device Quarantine Group.