Applies to NetApp E-Series EF300 and EF600 ATP M.2 mSATA device mSATA device firmware: Q0810B Issue EF300 or EF600 controller boots into UEFI boot menu following a reset. The controller continues to b...Applies to NetApp E-Series EF300 and EF600 ATP M.2 mSATA device mSATA device firmware: Q0810B Issue EF300 or EF600 controller boots into UEFI boot menu following a reset. The controller continues to boot into the UEFI menu even after manual reboot attempts.
EF300 and EF600 with NVME drives AND the following conditions: Data Assurance is disabled on one or more volumes in a volume group EF-Series controller(s) reboot randomly and may cause volume failures...EF300 and EF600 with NVME drives AND the following conditions: Data Assurance is disabled on one or more volumes in a volume group EF-Series controller(s) reboot randomly and may cause volume failures. SERR Return Status: 0x00000000 PCI-E Root to PLX9797-1 (Unit 1) PCI-E XP Uncorrectable Status = 0x00000040 PLX9797-1 Port 0 to Drive11 (Unit 15) PCI-E Device Status = 0x000D PCI-E AER Uncorrectable Status = 0x00100000 PCI-E AER Correctable Status = 0x00008000
Applies to NetApp E-Series EF600 NetApp E-Series EF300 Issue E-Series EF300 and EF600 controller(s) report a failed host interface card, but initiators are able to process I/Os to the controller(s). T...Applies to NetApp E-Series EF600 NetApp E-Series EF300 Issue E-Series EF300 and EF600 controller(s) report a failed host interface card, but initiators are able to process I/Os to the controller(s). The recovery guru failure code is either REC_HOST_BOARD_FAULT OR HOST_BOARD_FAULT_REPLACE_HIC-Recovery Failure Type Code: 105
Applies to EF300 EF600 Issue When attempting to boot an EF300 or EF600 with 120v lines the controllers do not fully power on and show OE L3 on the 7-segment display. When initializing the installation...Applies to EF300 EF600 Issue When attempting to boot an EF300 or EF600 with 120v lines the controllers do not fully power on and show OE L3 on the 7-segment display. When initializing the installation, you may encounter an issue where you cannot set the admin password.
SANtricity OS 11.70.5 and later System generates false alerts and does a software reset. =================== BMC Reboot Reason and Info ====================== [Sat Jan 1 00:00:31 2000] [0x09] Reboot: ...SANtricity OS 11.70.5 and later System generates false alerts and does a software reset. =================== BMC Reboot Reason and Info ====================== [Sat Jan 1 00:00:31 2000] [0x09] Reboot: FPGA pull BMC CPU only reset Example of false events/alerts: MAJOR-EVENT-LOG indicates BMC is unresponsive 2868 The controller's BMC was unresponsive and the recovery process successfully recovered the BMC - Shelf 99, Bay A 2867 The controller's BMC is unresponsive - Shelf 99, Bay A