    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/Uncorrectable_memory_errors_on_SF_Series_storage_nodes
      Applies to NetApp SolidFire SF-Series Issue On NetApp SolidFire Active IQ: Uncorrectable ECC error detected On iDRAC alert logs: CPU state: IERR Node offline and IPMI log detects: Uncorrectable ECC (U...Applies to NetApp SolidFire SF-Series Issue On NetApp SolidFire Active IQ: Uncorrectable ECC error detected On iDRAC alert logs: CPU state: IERR Node offline and IPMI log detects: Uncorrectable ECC (UnCorrectable ECC | DIMMB1, DIMMB2)
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/AFF_A800_unexpected_reboot_with_ECC_error_at_DIMM-XX
      SKL_IMC0 Error: STATUS<0xfe00a84001010090>(VALID,OVERFLOW,UC,EN,MISCV,ADDRV,PCC,CORR_ERR_STATUS(0),CORR_ERR_CNT(0x2a1),OTHER_INFO(0),MscodDdrType(0x1),MscodDataRdErr,MCACOD(0x90))MISC<0x200002c1200020...SKL_IMC0 Error: STATUS<0xfe00a84001010090>(VALID,OVERFLOW,UC,EN,MISCV,ADDRV,PCC,CORR_ERR_STATUS(0),CORR_ERR_CNT(0x2a1),OTHER_INFO(0),MscodDdrType(0x1),MscodDataRdErr,MCACOD(0x90))MISC<0x200002c120002086>(DataErrorChunk(0x2),McCmdChnl(0),McCmdMemRegion(0),McCmdOpcode(0x2),McCmdVld,SmiAD,SmiMsgClass(0),SmiOpcode(0x2),TrkId(0x100),Error_Type(0x4),ADDRMODE(0x2),ADDRLSB(0x6))ADDR<0x0000000e8a61ae40>(HIPHYADDR(0xe),LOPHYADDR(0x22986b9))(Node(1), Memory controller(0), CH(0), DIMM(1), Rank(5), Bank Gro…
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/H615C__DIMM_initialization_fail_CPU1_A0_Asserted
      BMC > System Inventory, there is a DIMM with the size: 16384MB BMC > IPMI Event Log > Event logs show DIMM initialization fail. (CPU1_A0) - Asserted [Warning] [Extended DIMM POST Error] [OEM Record C1...BMC > System Inventory, there is a DIMM with the size: 16384MB BMC > IPMI Event Log > Event logs show DIMM initialization fail. (CPU1_A0) - Asserted [Warning] [Extended DIMM POST Error] [OEM Record C1] ManufacturerID:000315, Major Code:0A, Minor Code:03 (CPU1_A0) [Warning] [Extended DIMM POST Error] [OEM Record C1] ManufacturerID:000315, Major Code:30, Minor Code:2D (CPU1_A0) [Warning] [POST Error] [System Firmware Progress] 0xA240 : DIMM initialization fail. (CPU1_A0) - Asserted
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/System_fails_to_boot_with_message_BIOS_detected_errors_or_invalid_configuration_in_DIMM_slot__XX
      Applies to FAS2240 FAS2552 Issue The storage systems fails to boot with the below error message and halts by itself: BIOS detected errors or invalid configuration in DIMM slot: XX Boot Loader version ...Applies to FAS2240 FAS2552 Issue The storage systems fails to boot with the below error message and halts by itself: BIOS detected errors or invalid configuration in DIMM slot: XX Boot Loader version 4.1 Copyright (C) 2000-2003 Broadcom Corporation. Portions Copyright (C) 2002-2011 NetApp CPU Type: Intel(R) Xeon(R) CPU C3528 @ 1.73GHz BIOS POST Failure(s) detected. Abort AUTOBOOT
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Multiple_PANICs_in_same_DIMM_slot_after_its_replacement
      ECC error at DIMM-17: 2C-0F-2007-2664E452,ADDR 0x19da7c2c80,(Node(0), Memory controller(0), CH(0), DIMM(0), Rank(0), Bank Group(0), Bank(0x3), Row(0x4785), Col(0x38)) SKL_IMC0 Error: STATUS<0xfe100000...ECC error at DIMM-17: 2C-0F-2007-2664E452,ADDR 0x19da7c2c80,(Node(0), Memory controller(0), CH(0), DIMM(0), Rank(0), Bank Group(0), Bank(0x3), Row(0x4785), Col(0x38)) SKL_IMC0 Error: STATUS<0xfe10000001010090>(VALID,OVERFLOW,UC,EN,MISCV,ADDRV,PCC,CORR_ERR_STATUS(0),CORR_ERR_CNT(0x4000),OTHER_INFO(0),MscodDdrType(0x1),MscodDataRdErr,MCACOD(0x90))MISC<0x200000c000202086>(DataErrorChunk(0x2),McCmdChnl(0),McCmdMemRegion(0),McCmdOpcode(0),McCmdVld,SmiAD,SmiMsgClass(0),SmiOpcode(0),TrkId(0x1),Error_T…