AFF C190 AFF A220 AFF A800 FAS2750 Controller attention LED on. BMC output of AFF A800 of command system fru led show all will report FRU LED ID 1 is on FRU LED ID 3 is on. FRU LED ID 4 is off BMC out...AFF C190 AFF A220 AFF A800 FAS2750 Controller attention LED on. BMC output of AFF A800 of command system fru led show all will report FRU LED ID 1 is on FRU LED ID 3 is on. FRU LED ID 4 is off BMC output of AFF C190, AFF A200, FAS2750 command system fru led show all will report BMC node_name> system fru led show all FRU LED ID 1 is off FRU LED ID 2 is on. Set by Expander/BMC FRU LED ID 3 is off FRU LED ID 4 is on FRU LED ID 5 is off FRU LED ID 6 is off FRU LED ID 7 is off FRU LED ID 8 is off
Cluster ports e0a/e0b links flap or go down at the same time, with or without a node takeover. This could be caused by hardware failure on one of the nodes. KB article provides steps to identify the a...Cluster ports e0a/e0b links flap or go down at the same time, with or without a node takeover. This could be caused by hardware failure on one of the nodes. KB article provides steps to identify the affected node and resolve the issue.
AutoSupport is triggered that the chassis power supply are degraded. HA Group Notification from node-02 (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR [node-02: monitor: mon...AutoSupport is triggered that the chassis power supply are degraded. HA Group Notification from node-02 (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR [node-02: monitor: monitor.globalStatus.critical:EMERGENCY]: Power Supply Status Critical: PSU1, PSU2. [node-02: power_low_monitor: monitor.chassisPowerSupplies.ok:info]: Chassis power supplies OK [node-02: monitor: monitor.globalStatus.ok:info]: The system's global status is normal
After a node panics due to the boot device becoming unreadable, the node loses configuration When attempting to boot the node after the panic, messages such as this are seen: [nv2flash.misc.dbg:NOTICE...After a node panics due to the boot device becoming unreadable, the node loses configuration When attempting to boot the node after the panic, messages such as this are seen: [nv2flash.misc.dbg:NOTICE]: nv2f_write_msg_to_flash: Failed to write flash at offset 0x55200 ret -1.Error on reading meta data header! WARNING: Failed to restore /var from /dev/nvrd1. ERROR: netapp_varfs: Failed to restore /var from /dev/nvrd1 after clean shutdown. The node boots into the cluster setup wizard:
Applies to NetApp AFF and FAS systems ONTAP 9 Service Processor - SP Baseboard Management Controller - BMC Management port - e0M Issue Unable to connect to the service processor via SSH, firmware imag...Applies to NetApp AFF and FAS systems ONTAP 9 Service Processor - SP Baseboard Management Controller - BMC Management port - e0M Issue Unable to connect to the service processor via SSH, firmware image and version is seen as "unknown". Refer to the additional information section for more details.