After a reboot, one of the nodes reports the SP status as degraded: Node Type Status Configured Version IP Address cluster1-03 SP online true 4.11 10.152.118.255 cluster1-04 SP degraded true 4.11 10.1...After a reboot, one of the nodes reports the SP status as degraded: Node Type Status Configured Version IP Address cluster1-03 SP online true 4.11 10.152.118.255 cluster1-04 SP degraded true 4.11 10.152.118.254 When looking sysconfig -a, we see the SP degraded, as well as no network configuration present: Service Processor Status: Degraded [cluster1-04: nphmd: hm.alert.raised:alert]: Alert Id = SPNotConfiguredAlert , Alerting Resource = SP Config raised by monitor controller
Applies to FAS9000 SP 4.11 ONTAP 9 Issue A FAS9000 node reboots due to unreadable battery sensors: [cluster1-04: env_mgr: nvram.battery.sensor.unreadable:EMERGENCY]: The NVRAM battery state cannot be ...Applies to FAS9000 SP 4.11 ONTAP 9 Issue A FAS9000 node reboots due to unreadable battery sensors: [cluster1-04: env_mgr: nvram.battery.sensor.unreadable:EMERGENCY]: The NVRAM battery state cannot be determined because the 'Bat Cycle Count' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes. [cluster1-04: env_mgr: callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Cycle Count' unreadable) CRITICAL.